Determination of polycyclic aromatic hydrocarbons in waste water by off-line coupling of solid-phase microextraction with column liquid chromatography

被引:79
作者
Popp, P
Bauer, C
Möder, M
Paschke, A
机构
[1] UFZ Helmholtz Ctr Environm Res, Environm Res Ctr Leipzig Halle, Dept Analyt Chem, D-04318 Leipzig, Germany
[2] UFZ Helmholtz Ctr Environm Res, Environm Res Ctr Leipzig Halle, Dept Chem Ecotoxicol, D-04318 Leipzig, Germany
关键词
solid-phase microextraction; polynuclear aromatic hydrocarbons;
D O I
10.1016/S0021-9673(00)00820-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new method for the determination of polycyclic aromatic hydrocarbons (PAHs) in waste water using solvent-free solid-phase microextraction (SPME) is described. The PAHs are extracted with a 100 mum polydimethylsiloxane (PDMS) fiber, desorbed in 40 mul acetonitrile and measured with LC and fluorescence detection. The detection limits of this very simple method under the given conditions (extraction from 5 mi sample, extraction time 1 h) are in the range of 1-6 ng l(-1). The standard deviations (n=6) at a concentration level of 0.8 mug l(-1) are between 1.8 and 14.4%. The procedure was used for the determination of PAHs in contaminated water samples. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:153 / 159
页数:7
相关论文
共 18 条
[1]  
Belardi R.P., 1989, WATER POLLUT RES J C, V24, P179, DOI [10.2166/wqrj.1989.010, DOI 10.2166/WQRJ.1989.010]
[2]   Solid-phase microextraction coupled with high-performance liquid chromatography for the determination of alkylphenol ethoxylate surfactants in water [J].
BoydBoland, AA ;
Pawliszyn, JB .
ANALYTICAL CHEMISTRY, 1996, 68 (09) :1521-1529
[3]   DETERMINATION OF POLYCYCLIC AROMATIC-HYDROCARBONS IN SURFACE-WATER BY COLUMN LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION, USING ONLINE MICELLE-MEDIATED SAMPLE PREPARATION [J].
BROUWER, ER ;
HERMANS, ANJ ;
LINGEMAN, H ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY A, 1994, 669 (1-2) :45-57
[4]   SOLID-PHASE MICROEXTRACTION COUPLED TO HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CHEN, J ;
PAWLISZYN, JB .
ANALYTICAL CHEMISTRY, 1995, 67 (15) :2530-2533
[5]   Development of a prototype system for quasi-continuous analysis of organic contaminants in surface or sewage water based on in-line coupling of solid-phase microextraction to gas chromatography [J].
Eisert, R ;
Levsen, K .
JOURNAL OF CHROMATOGRAPHY A, 1996, 737 (01) :59-65
[6]   Determination and stability of pesticides in freeze-dried water samples by automated on-line solid-phase extraction followed by liquid chromatography with diode-array detection [J].
Ferrer, I ;
Barcelo, D .
JOURNAL OF CHROMATOGRAPHY A, 1996, 737 (01) :93-99
[7]  
Jia CR, 1998, J MICROCOLUMN SEP, V10, P167, DOI 10.1002/(SICI)1520-667X(1998)10:2<167::AID-MCS1>3.0.CO
[8]  
2-E
[9]   Analysis of pesticides in environmental water samples by solid-phase micro-extraction-high-performance liquid chromatography [J].
Jinno, K ;
Muramatsu, T ;
Saito, Y ;
Kiso, Y ;
Magdic, S ;
Pawliszyn, J .
JOURNAL OF CHROMATOGRAPHY A, 1996, 754 (1-2) :137-144
[10]   DYNAMICS OF ORGANIC-COMPOUND EXTRACTION FROM WATER USING LIQUID-COATED FUSED-SILICA FIBERS [J].
LOUCH, D ;
MOTLAGH, S ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1992, 64 (10) :1187-1199