Facial anthropometric dimensions of Koreans and their associations with fit of quarter-mask respirators

被引:47
作者
Kim, H
Han, DH
Rohi, YM
Kim, K
Park, YG
机构
[1] Catholic Univ Korea, Coll Med, Dept Biostat, Seocho Gu, Seoul 137701, South Korea
[2] Korean Ind Hlth Assoc, Inst Occupat Hlth, Seoul, South Korea
[3] Inje Univ, Dept Ind Hlth & Safety, Gyongnam Do, Gimhae, South Korea
[4] Catholic Univ, Coll Med, Dept Prevent Med, Seoul, South Korea
关键词
anthropometry; facial dimensions; Korean; quantitative fit factor; quarter mask;
D O I
10.2486/indhealth.41.8
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Past studies on respirator fit or performance have mostly been done for Whites or male subjects, and little attention has been paid to minorities and Asians. To rill this gap, this study was designed to provide facial anthropometric data for Koreans and to analyze the association between facial dimensions and respirator fit factors for three brands of quarter-mask respirators, two domestic and one imported brand, using a Portacount(TM) 8020. A total of 110 university student subjects, 70 males and 40 females volunteered for participation in the study. The results of this study showed that Korean males and females have different facial dimensions as compared with those of White males and females. Unexpectedly, the imported respirator performed better than the domestic respirators. Males were found to achieve better respirator fit than females regardless of respirator brands tested. The regression analysis found no common prognostic variables with the three respirator brands studied. A stepwise logistic regression analysis was conducted to rind predictive facial dimensions with respirator fits. Some facial dimensions were found to be statistically significant, but these dimensions are different from the traditionally recommended facial dimensions of face length and lip width for quarter mask. To improve respirator fit for Koreans, these different facial characteristics need to be considered in the design of quarter mask respirators.
引用
收藏
页码:8 / 18
页数:11
相关论文
共 27 条
[1]  
[Anonymous], 1995, APPL OCCUP ENVIRON H
[2]  
*ANSI, 1992, 8821992 ANSI Z
[3]  
*ANTHR BRANS, 1967, USAIR FORC ANTHR SUR
[4]  
Brazile WJ., 1998, Applied Occupational and Environmental Hygiene, V13, P233, DOI [DOI 10.1080/1047322X.1998, DOI 10.1080/1047322X.1998.10390073]
[5]  
CROSBY DW, 1995, RESP PROTECTION UPDA, V6
[6]  
Gross S. F., 1990, APPL OCCUP ENV HYG, V5, P229, DOI DOI 10.1080/1047322X.1990.10389628
[7]   RESPIRATOR PROTECTION FACTORS .1. DEVELOPMENT OF AN ANTHROPOMETRIC TEST PANEL [J].
HACK, AL ;
MCCONVILLE, JT .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1978, 39 (12) :970-975
[8]  
HACK AL, 1974, SELECTION RESP TEST
[9]  
Han D.-H., 1999, KOREAN IND HYG ASS J, V9, P1
[10]  
Han DH, 1997, AM IND HYG ASSOC J, V58, P219, DOI 10.1202/0002-8894(1997)058<0219:QFTTAR>2.0.CO