Initial fixation strength of polylactic acid interference screws in anterior cruciate ligament reconstruction

被引:49
作者
Abate, JA
Fadale, PD
Hulstyn, MJ
Walsh, WR
机构
[1] Univ Vermont, Coll Med, Dept Orthopaed & Rehabil, Mcclure Musculoskeletal Res Ctr,Div Sports Med, Burlington, VT 05405 USA
[2] Brown Univ, Sch Med Rhode Isl, Dept Orthopaed Surg, Div Sports Med, Providence, RI 02912 USA
[3] Univ New S Wales, Prince Wales Hosp, Grad Sch Biomed Engn, Sydney, NSW, Australia
[4] Univ New S Wales, Prince Wales Hosp, Dept Orthopaed, Sydney, NSW, Australia
来源
ARTHROSCOPY | 1998年 / 14卷 / 03期
关键词
polylactic acid; interference screw; ACL reconstruction; bovine model;
D O I
10.1016/S0749-8063(98)70143-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The initial fixation properties of bioresorbable polylactic acid (PLA) interference screws designed for anterior cruciate ligament reconstruction were evaluated using an in vitro bovine model. The surgical technique of interference screw fixation of the bone-patellar tendon-bone autograft complex performed clinically was reproduced in an adult bovine model. The reconstructed knee was tested oriented in 30 degrees of flexion to allow examination of the femoral and tibial fixation properties simultaneously. This model examined the initial fixation strength between PLA and metal interference screws as well as a partially degraded PLA implant. Data from this in vitro model indicate that PLA interference screws can provide similar initial fixation at both time 0 and after degradation for up to 28 days compared with metal interference screws for bone-tendon-bane ACL reconstructions.
引用
收藏
页码:278 / 284
页数:7
相关论文
共 21 条
[1]   THE EFFECTS OF SIMULATED WEIGHTLESSNESS ON BONE BIOMECHANICAL AND BIOCHEMICAL-PROPERTIES IN THE MATURING RAT [J].
ABRAM, AC ;
KELLER, TS ;
SPENGLER, DM .
JOURNAL OF BIOMECHANICS, 1988, 21 (09) :755-&
[2]   PRELIMINARY-RESULTS OF AN ABSORBABLE INTERFERENCE SCREW [J].
BARBER, FA ;
ELROD, BF ;
MCGUIRE, DA ;
PAULOS, LE .
ARTHROSCOPY, 1995, 11 (05) :537-548
[3]   DOES CORROSION MATTER [J].
BLACK, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (04) :517-520
[4]   ABSORBABLE IMPLANTS FOR THE FIXATION OF FRACTURES [J].
BOSTMAN, OM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (01) :148-153
[5]  
BUCHOLZ R, 1992, J ORTHOP TRAUMA, V6, P505
[6]  
COWIN SC, 1987, HDB BIOENGINEERING, pCH3
[7]  
DANIEL DM, 1990, KNEE LIGAMENTS STRUC, P11
[8]  
HECKER AT, 1992, P 38 ANN M ORTH RES, P219
[9]  
HOLLINGER JO, 1986, CLIN ORTHOP RELAT R, P290
[10]   BIOMECHANICAL EVALUATION OF INTERFERENCE SCREW FIXATION IN A BOVINE PATELLAR BONE TENDON BONE AUTOGRAFT COMPLEX FOR ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION [J].
HULSTYN, M ;
FADALE, PD ;
ABATE, J ;
WALSH, WR .
ARTHROSCOPY, 1993, 9 (04) :417-424