A lead (II)-selective PVC membrane based on a Schiff base complex of N,N'-bis(salicylidene)-2,6-pyridinediamine

被引:79
作者
Jeong, T [1 ]
Lee, HK [1 ]
Jeong, DC [1 ]
Jeon, S [1 ]
机构
[1] Chonnam Natl Univ, Inst Basic Sci, Dept Chem, Kwangju 500757, South Korea
关键词
polymeric membrane; lead ion; ion-selective electrode; N,N'-bis(salicylidene)-2,6-pyridinediamine; Schiff base;
D O I
10.1016/j.talanta.2004.07.016
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
PVC membrane electrodes for lead ion based on N,N'-bis(salicylidene)-2,6-pyridinediamine as membrane carrier were prepared. Among their membranes. a membrane electrode (m-3) containing o-NPOE as a plasticizer and 50 mol% additive displays an excellent Nernstian response (29.4 mV/decade) and the limit of detection of -log a (M) = 6.04 to Pb2+ in Pb(NO3)(2) solutions at room temperature. It has a rapid response nine within 10 s over the entire concentration range. The proposed electrode revealed good selectivity and response for W over a wide variety of other metal ions in a pH 5.0 buffer Solutions, and good reproducibility of base line in subsequent measurements. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:543 / 548
页数:6
相关论文
共 46 条
[1]   Aluminium(III)-selective electrode based on a newly synthesized tetradentate Schiff base [J].
Abbaspour, A ;
Esmaeilbeig, AR ;
Jarrahpour, AA ;
Khajeh, B ;
Kia, R .
TALANTA, 2002, 58 (02) :397-403
[2]   Lead(II)-selective electrode based on phenyl disulfide [J].
Abbaspour, A ;
Khajeh, B .
ANALYTICAL SCIENCES, 2002, 18 (09) :987-991
[3]   Lead-selective electrode by using benzyl disulphide as ionophore [J].
Abbaspour, A ;
Tavakol, F .
ANALYTICA CHIMICA ACTA, 1999, 378 (1-3) :145-149
[4]   Copper(II)-selective membrane electrode based on a recently synthesized naphthol-derivative Schiff's base [J].
Alizadeh, N ;
Ershad, S ;
Naeimi, H ;
Sharghi, H ;
Shamsipur, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 365 (06) :511-515
[5]   A new lead(II)-selective PVC-coated graphite rod electrode based on a Schiff base complex [J].
Arida, HA ;
El-Reefy, SA ;
El-Saied, AM .
ANALYTICAL SCIENCES, 2003, 19 (05) :687-690
[6]   Lead selective electrodes based on calixarene phosphine oxide derivatives [J].
Cadogan, F ;
Kane, P ;
McKervey, MA ;
Diamond, D .
ANALYTICAL CHEMISTRY, 1999, 71 (24) :5544-5550
[7]  
Casado M, 2001, ELECTROANAL, V13, P54, DOI 10.1002/1521-4109(200101)13:1<54::AID-ELAN54>3.0.CO
[8]  
2-1
[9]  
Choi YK, 1999, ELECTROANAL, V11, P134, DOI 10.1002/(SICI)1521-4109(199902)11:2<134::AID-ELAN134>3.3.CO
[10]  
2-Z