Detection of β-lactamase reporter gene expression by flow cytometry

被引:26
作者
Knapp, T
Hare, E
Feng, LX
Zlokarnik, G
Negulescu, P
机构
[1] Vertex Pharmaceut Inc, San Diego, CA 92121 USA
[2] Univ Calif San Diego, San Diego, CA 92103 USA
关键词
flow cytometry; fluorescence resonance energy transfer; beta-lactamase; beta-galactosidase; lacZ; CCF2; rare event; reporter gene; diode laser;
D O I
10.1002/cyto.a.10018
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Flow cytometry of gene expression in living cells requires accurate, sensitive, nontoxic fluorescent indicators capable of detecting transcription of specific genes. This is typically achieved by using genes that encode fluorescent proteins or enzymes coupled to promoters of interest. The most commonly used reporters are green fluorescent protein and beta-galactosidase (lacZ). In this study, we characterized the performance of a cell-permeant, ratiometric, beta-lactamase substrate, coumarin cephalosporin fluorescein (CCF2/AM). We compared its characteristics with that of the beta-galactosidase/fluorescein di-beta-D-galactopyranoside reporter system. Methods: Jurkat cell lines were generated for beta-lactamase and beta-galactosidase reporters with the use of similar plasmid constructs. Rare event flow cytometric detection for the beta-galactosidase and beta-lactamase reporters were assayed by using mixed populations of negative (WT) and positive (constitutively expressing) cells for each reporter. To determine sensitivity at low reporter copy number, we measured the activity of an unstimulated inducible promoter and detected positive events as a function of substrate incubation time. Technical issues related to data processing and optical configuration are also presented. Results: The low population coefficients of variation afforded by ratiometric detection of the beta-lactamase system improved the statistical performance of the assay in comparison with a single-dye, intensity-based assay, leading to markedly improved detection for low copy number and rare events. At low levels of gene expression, beta-lactamase was detected with approximately 10-fold higher confidence than was beta-galactosidase. In rare event detection experiments, cells expressing high levels of beta-lactamase proteins were reliably detected at frequencies of 1:106 compared with about 1:104 for beta-galactosidase. Conclusion: The ratiometric fluorescence readout of the beta-lactamase system based on fluorescence resonance energy transfer allowed more sensitive and accurate detection of gene expression than the currently available beta-galactosidase substrates. Further, the cell-permeant nature of the substrate improved experimental convenience. These properties facilitated cell engineering and enabled a variety of applications including selection of rare cells from large populations and measurement of low-expressing or downregulated genes. Cytometry Part A 51A:68-78, 2003. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:68 / 78
页数:11
相关论文
共 21 条
[1]   A SINGLE LASER METHOD FOR SUBTRACTION OF CELL AUTOFLUORESCENCE IN FLOW-CYTOMETRY [J].
ALBERTI, S ;
PARKS, DR ;
HERZENBERG, LA .
CYTOMETRY, 1987, 8 (02) :114-119
[2]   Simultaneous fluorescence-activated cell sorter analysis of two distinct transcriptional elements within a single cell using engineered green fluorescent proteins [J].
Anderson, MT ;
Tjioe, IM ;
Lorincz, MC ;
Parks, DR ;
Herzenberg, LA ;
Nolan, GP ;
Herzenberg, LA .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1996, 93 (16) :8508-8511
[3]   AUTOFLUORESCENCE OF VIABLE CULTURED MAMMALIAN-CELLS [J].
AUBIN, JE .
JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1979, 27 (01) :36-43
[4]  
CAMPBELL RM, 1993, DEVELOPMENT, V119, P1217
[5]   FLOW CYTOMETRIC ANALYSIS OF MURINE SPLENIC LYMPHOCYTE-B CYTOSOLIC FREE CALCIUM RESPONSE TO ANTI-IGM AND ANTI-IGD [J].
CHUSED, TM ;
WILSON, HA ;
GREENBLATT, D ;
ISHIDA, Y ;
EDISON, LJ ;
TSIEN, RY ;
FINKELMAN, FD .
CYTOMETRY, 1987, 8 (04) :396-404
[6]  
DIVIRGILIO F, 1988, J IMMUNOL, V140, P915
[7]   IMPROVED FACS-GAL - FLOW CYTOMETRIC ANALYSIS AND SORTING OF VIABLE EUKARYOTIC CELLS EXPRESSING REPORTER GENE CONSTRUCTS [J].
FIERING, SN ;
ROEDERER, M ;
NOLAN, GP ;
MICKLEM, DR ;
PARKS, DR ;
HERZENBERG, LA .
CYTOMETRY, 1991, 12 (04) :291-301
[8]   DETECTION OF RARE CELLS AT A FREQUENCY OF ONE PER MILLION BY FLOW-CYTOMETRY [J].
GROSS, HJ ;
VERWER, B ;
HOUCK, D ;
RECKTENWALD, D .
CYTOMETRY, 1993, 14 (05) :519-526
[9]   MODEL STUDY DETECTING BREAST-CANCER CELLS IN PERIPHERAL-BLOOD MONONUCLEAR-CELLS AT FREQUENCIES AS LOW AS 10(-7) [J].
GROSS, HJ ;
VERWER, B ;
HOUCK, D ;
HOFFMAN, RA ;
RECKTENWALD, D .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1995, 92 (02) :537-541
[10]  
LEARY JF, 1994, METHOD CELL BIOL, V42, P331