A comparison of the ProSeal and classic laryngeal mask airways for airway management by inexperienced personnel after manikin-only training

被引:33
作者
Coulson, A
Brimacombe, J
Keller, C
Wiseman, L
Ingham, T
Cheung, D
Popwycz, L
Hall, B
机构
[1] James Cook Univ N Queensland, Dept Anaesthesia & Intens Care, Cairns Base Hosp, Cairns, Qld 4870, Australia
[2] Univ Queensland, St Lucia, Qld 4067, Australia
[3] Leopold Franzens Univ, Dept Anaesthesia & Intens Care Med, Innsbruck, Austria
关键词
equipment : ProSeal laryngeal mask airway; classic laryngeal mask airway; manikin; airway : technique; cardiopulmonary resuscitation : training; inexperienced personnel;
D O I
10.1177/0310057X0303100308
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We compared the ProSeal(TM) (PLMA) and Classic(TM) (LMA) laryngeal mask airway for airway management by inexperienced personnel. Nine nurses from the post-anaesthesia care unit, with no prior experience of LMA or PLMA insertion, were observed inserting the LMA and PLMA in 60 ASA 1 to 2 anaesthetized, paralysed adults following manikin-only training. The time to achieve an effective airway (2 consecutive expired tidal volumes (6 ml/kg; maximum 2 minutes allowed), the number of insertion attempts and the reasons for failure (inability to insert into pharynx or inadequate ventilation) were determined by analysis of digital video recordings. The first attempt success rate (LMA, 85%; PLMA, 83%), overall success rate (LMA, 88%; PLMA, 90%) and effective airway time (LMA, 39+/-13s; PLMA, 43+/-19s) were similar Failure was from an inability to insert into the pharynx in five with the LMA and three with the PLMA, and inadequate ventilation with two from the LMA and three from the PLMA. Effective airway time and the number of failures were similar for the first and second device. Failure of both devices occurred in four patients. We conclude that airway management in anaesthetized, paralysed adults is equally successful for the LMA and PLMA by inexperienced personnel following manikin-only training. The PLMA is worthy of consideration as a tool for emergency airway management by inexperienced personnel.
引用
收藏
页码:286 / 289
页数:4
相关论文
共 15 条
[1]   Guidelines for the basic management of the airway and ventilation during resuscitation - A statement by the Airway and Ventilation Management Working Group of the European Resuscitation Council [J].
Baskett, PJF ;
Bossaert, L ;
Carli, P ;
Chamberlain, D ;
Dick, W ;
Nolan, JP ;
Parr, MJA ;
Scheidegger, D ;
Zideman, D ;
Blancke, W ;
Delooz, H ;
Handley, A ;
Kettler, D ;
Kloeck, W ;
Kramer, E ;
Quan, L ;
Studer, W ;
VanDrenth, A .
RESUSCITATION, 1996, 31 (03) :187-200
[2]   The LMA 'ProSeal' - a laryngeal mask with an oesophageal vent [J].
Brain, AIJ ;
Verghese, C ;
Strube, PJ .
BRITISH JOURNAL OF ANAESTHESIA, 2000, 84 (05) :650-654
[3]   The ProSeal laryngeal mask airway - A randomized, crossover study with the standard laryngeal mask airway in paralyzed, anesthetized patients [J].
Brimacombe, J ;
Keller, C .
ANESTHESIOLOGY, 2000, 93 (01) :104-109
[4]   A multicenter study comparing the ProSeal™ and Classic™ laryngeal mask airway in anesthetized, nonparalyzed patients [J].
Brimacombe, J ;
Keller, C ;
Fullekrug, B ;
Agrò, F ;
Rosenblatt, W ;
Dierdorf, SF ;
de Lucas, EG ;
Capdevilla, X ;
Brimacombe, N .
ANESTHESIOLOGY, 2002, 96 (02) :289-295
[5]   Positive pressure ventilation with the ProSeal versus classic laryngeal mask airway:: A randomized, crossover study of healthy female patients [J].
Brimacombe, J ;
Keller, C ;
Boehler, M ;
Pühringer, F .
ANESTHESIA AND ANALGESIA, 2001, 93 (05) :1351-1353
[6]  
Choyce A, 2000, BRIT J ANAESTH, V84, P103
[7]  
Choyce A, 2000, ANESTHESIOLOGY, V93, pU164
[8]   LARYNGEAL MASK AIRWAY AND TRACHEAL TUBE INSERTION BY UNSKILLED PERSONNEL [J].
DAVIES, PRF ;
TIGHE, SQM ;
GREENSLADE, GL ;
EVANS, GH .
LANCET, 1990, 336 (8721) :977-979
[9]   INTRODUCTION TO BIOSTATISTICS .5. STATISTICAL-INFERENCE TECHNIQUES FOR HYPOTHESIS-TESTING WITH NONPARAMETRIC DATA [J].
GADDIS, GM ;
GADDIS, ML .
ANNALS OF EMERGENCY MEDICINE, 1990, 19 (09) :1054-1059
[10]  
*LAR MASK COMP LTD, 2000, LMA PROS INSTR MAN