A simple micro-growth assay for enumerating bacteria

被引:67
作者
Brewster, JD [1 ]
机构
[1] USDA ARS, Eastern Reg Res Ctr, Philadelphia, PA 19038 USA
关键词
bacteria; enumeration; counting;
D O I
10.1016/S0167-7012(02)00226-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple method for nonspecific determination of bacteria concentrations in a variety of liquid samples was developed. The assay was based on the time required for a sample grown in liquid media to reach a threshold turbidity. Samples were combined with media in a covered 96-well microwell plate and the turbidity was monitored in real time as the bacteria grew in a temperature-control led plate reader. A significant problem with growth in microwells was condensation on the cover, which prevented accurate turbidity measurement. This problem was overcome by coating the cover with a small amount of surface-active agent. Salmonella and E. coli concentrations could be determined with a relative error of approximately 20% at levels from 10 to 10(6) cells/ml (eight replicates). An assay of 10 samples with standards required 10 min to set up and 20 min for data processing using a computer spreadsheet program. Growth time at 37 degreesC ranged from 4 h for samples at 10(7) cells/ml to 16 h for samples at 10 cells/ml. (C) 2002 Elsevier Science B.V All rights reserved.
引用
收藏
页码:77 / 86
页数:10
相关论文
共 12 条
[1]  
BROWN DFJ, 1981, RAPID METHODS AUTOMA, P171
[2]   When is simple good enough: A comparison of the Gompertz, Baranyi, and three-phase linear models for fitting bacterial growth curves [J].
Buchanan, RL ;
Whiting, RC ;
Damert, WC .
FOOD MICROBIOLOGY, 1997, 14 (04) :313-326
[3]  
COLLIN CH, 1995, AUTOMATED METHODS CO, P121
[4]   MICROTITER METHOD FOR EVALUATION OF VIABLE CELLS IN BACTERIAL CULTURES [J].
FUNG, DYC ;
KRAFT, AA .
APPLIED MICROBIOLOGY, 1968, 16 (07) :1036-&
[5]  
GILCHRIST JE, 1977, J ASSOC OFF ANA CHEM, V60, P807
[6]  
GILCHRIST JE, 1972, APPL MICROBIOL, V25, P244
[7]   Immuno-magnetic bead mass transport and capture efficiency at low target cell densities in phosphate-buffered saline [J].
Irwin, P ;
Damert, W ;
Brewster, J ;
Gehring, A ;
Tu, SI .
JOURNAL OF RAPID METHODS AND AUTOMATION IN MICROBIOLOGY, 2002, 10 (02) :129-147
[8]   EVALUATION AND OPTIMIZATION OF URINE SCREENING BY AUTOBAC [J].
KELLY, MT ;
BALFOUR, LC .
JOURNAL OF CLINICAL MICROBIOLOGY, 1981, 13 (04) :677-680
[9]   AUTOMATED TURBIDOMETRY - A METHOD FOR ENUMERATION OF BACTERIA IN FOOD SAMPLES [J].
MATTILA, T .
JOURNAL OF FOOD PROTECTION, 1987, 50 (08) :640-642
[10]   MICROTECHNIQUE FOR MOST-PROBABLE-NUMBER ANALYSIS [J].
ROWE, R ;
TODD, R ;
WAIDE, J .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1977, 33 (03) :675-680