Efficacy of heat and moisture exchangers after changing every 48 hours rather than 24 hours

被引:32
作者
Thomachot, L [1 ]
Vialet, R [1 ]
Viguier, JM [1 ]
Sidier, B [1 ]
Roulier, P [1 ]
Martin, C [1 ]
机构
[1] Hop Nord Marseille, Dept Anesthesie Reanimat, F-13915 Marseille 20, France
关键词
absolute humidity; heat and moisture exchanger; heated humidifier system; humidification of inspired gases; mechanical ventilation; nebulizer; relative humidity; tracheal intubation; vaporizer;
D O I
10.1097/00003246-199803000-00018
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To determine whether changing heat and moisture exchangers every 48 hrs rather than 24 hrs would affect their efficacy to preserve heat and moisture of expiratory gases. Design: Prospective, controlled, randomized, not blinded, study. Setting: Intensive care unit of a university hospital. Patients: Twenty-nine patients requiring controlled mechanical ventilation and paralysis for >2 days. Interventions: After randomization, the patients were allocated to one of the three following groups: a) group 1, ventilated for 24 hrs with a heat and moisture exchanger; b) group 2, ventilated for 48 hrs with the same heat and moisture exchanger; and c) group 3, ventilated for 48 hrs with a heated humidifier system. Measurements and Main Results: in each patient, during the inspiration phase, the following measurements were performed: a) peak and mean airway pressures; b) mean values of temperature; c) relative and absolute humidity of inspired gases. in each patient, measurements were performed after 24 hrs and after 48 hrs, where appropriate; After 24 hrs, patients in groups 1 and 2 had similar levels of temperature (30.1 +/- 2.7 degrees C and 29.2 +/- 2.3 degrees C), relative humidity (98.3 +/- 3.6% and 99.3 +/- 3.4%), and absolute humidity (29.1 +/- 2.1 and 29.3 +/- 2.4 mg H2O/L). Using the same heat and moisture exchanger for 48 hrs rather than 24 hrs did not affect its technical performance. Results showed the following: a) temperature, 24 hrs, 29.2 +/- 2.3 degrees C, 48 hrs, 28.7 +/- 1.9 degrees C; b) relative humidity, 24 hrs, 99.3 +/- 3.4%, 48 hrs, 99.2 +/- 1.7%; and c) absolute humidity, 24 hrs, 29.3 +/- 2.4 mg H2O/L, 48 hrs, 28.7 +/- 3.1 mg H2O/L. Peak and mean airway pressures did not change over the 48-hr study period, with identical tidal and minute volumes in the study patients. Higher levels of temperature and absolute humidity of inspired gases were observed in group 3, compared with groups 1 and 2 (p < .02). Conclusions: Changing the heat and moisture exchanger after 48 hrs rather than 24 hrs did not affect its technical performance in terms of heat and water preservation of ventilatory gases. There is also some indirect evidence of very few, if any, changes in heat and moisture exchanger resistance. However, other large clinical trials should be undertaken to confirm the safety of extending the time between heat and moisture exchanger change. The heated humidifier, supplied with electric energy maintained high levels of humidification and temperature over the 48-hr study period.
引用
收藏
页码:477 / 481
页数:5
相关论文
共 36 条
[1]  
BETHUNE DW, 1985, ANAESTHESIA, V40, P210
[2]   HUMIDIFICATION IN ANESTHESIA - REVIEW OF PRESENT SITUATION [J].
BOYS, JE ;
HOWELLS, TH .
BRITISH JOURNAL OF ANAESTHESIA, 1972, 44 (08) :879-+
[3]   HUMIDIFICATION IN THE INTENSIVE-CARE UNIT - PROSPECTIVE-STUDY OF A NEW PROTOCOL UTILIZING HEATED HUMIDIFICATION AND A HYGROSCOPIC CONDENSER HUMIDIFIER [J].
BRANSON, RD ;
DAVIS, K ;
CAMPBELL, RS ;
JOHNSON, DJ ;
POREMBKA, DT .
CHEST, 1993, 104 (06) :1800-1805
[4]   EFFECTS OF DRY ANESTHETIC GASES ON TRACHEOBRONCHIAL CILIATED EPITHELIUM [J].
CHALON, J ;
MALEBRANCHE, J ;
LOEW, DAY .
ANESTHESIOLOGY, 1972, 37 (03) :338-+
[5]   HUMIDITY AND THE ANESTHETIZED PATIENT [J].
CHALON, J ;
PATEL, C ;
ALI, M ;
RAMANATHAN, S ;
CAPAN, L ;
TANG, CK ;
TURNDORF, H .
ANESTHESIOLOGY, 1979, 50 (03) :195-198
[6]  
CHALON J, 1984, ANESTH ANALG, V1, P285
[7]  
CIGADA M, 1990, INTENSIVE CARE WORLD, V7, P98
[8]  
CRAVEN DE, 1984, AM REV RESPIR DIS, V129, P625
[9]   EVOLUTION OF HEAT AND MOISTURE IN RESPIRATORY TRACT DURING ANESTHESIA WITH A NON-REBREATHING SYSTEM [J].
DERY, R .
CANADIAN ANAESTHETISTS SOCIETY JOURNAL, 1973, 20 (03) :296-309
[10]  
DERY R., 1967, CAN ANAESTH SOC J, V14, P287, DOI 10.1007/BF03003698