Comparison of a digital and a handheld infrared pupillometer for determining scotopic pupil diameter

被引:69
作者
Kohnen, T [1 ]
Terzi, E [1 ]
Buhren, J [1 ]
Kohnen, EM [1 ]
机构
[1] Univ Frankfurt, Dept Ophthalmol, D-60590 Frankfurt, Germany
关键词
D O I
10.1016/S0886-3350(02)01898-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare a digital infrared pupillometer with a handheld infrared pupillometer for determining scotopic pupil size. Setting: Department of Ophthalmology, Johann Wolfgang Goethe-University, Frankfurt am Main, Germany. Methods: In 100 eyes of 50 healthy individuals (mean age 38.8 years +/- 10.7 [SD]), the scotopic pupil size was measured with a digital (Procyon) and a handheld (Colvard) infrared pupillometer. After dark adaptation of 1 minute, measurements were performed with both devices by 2 examiners (El and E2). Agreement and repeatability were analyzed using a comparison method described by Bland and Altman. Results: The mean scotopic pupil diameter was 5.90 +/- 0.97 mm (range 3.24 to 7.91 mm) with the Procyon and 5.78 +/- 0.98 mm (range 3.00 to 7.30 mm) with the Colvard pupillometer. The mean difference between the 2 devices was -0.01 mm (El) and -0.24 mm (E2). The limits of agreement ranged from 2.84 (El) to 3.24 (E2). The coefficients of repeatability were 0.64 (Procyon) and 1.16 (Colvard). The mean difference between El and E2 was -0.10 for the Procyon and 0.13 for the Colvard pupillometer. The limits of agreement ranged from 1.28 (Procyon) to 2.32 (Colvard). Conclusions: The digital infrared pupillometer (Procyon) demonstrated better repeatability and agreement in measuring scotopic pupil size than a handheld device (Colvard). (C) 2003 ASCRS and ESCRS.
引用
收藏
页码:112 / 117
页数:6
相关论文
共 18 条
[1]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[2]  
Applegate R A, 1990, Refract Corneal Surg, V6, P47
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   BASIC DATA FOR CLINICAL PUPILLOGRAPHY .3. AGE-DEPENDENCE OF LIGHT-REACTION [J].
BORGMANN, H .
ALBRECHT VON GRAEFES ARCHIV FUR KLINISCHE UND EXPERIMENTELLE OPHTHALMOLOGIE, 1972, 185 (01) :1-&
[5]   Preoperative measurement of scotopic pupil dilation using an office pupillometer [J].
Colvard, M .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (12) :1594-1597
[6]   THE RELATIONSHIP OF VISUAL-ACUITY, REFRACTIVE ERROR, AND PUPIL SIZE AFTER RADIAL KERATOTOMY [J].
HOLLADAY, JT ;
LYNN, MJ ;
WARING, GO ;
GEMMILL, M ;
KEEHN, GC ;
FIELDING, B .
ARCHIVES OF OPHTHALMOLOGY, 1991, 109 (01) :70-76
[7]  
KOCH DD, 1991, OPHTHALMOLOGY, V98, P1030
[8]  
Kohnen T, 2001, J CATARACT REFR SURG, V27, P1897
[9]  
Loewenfeld I. E., 1993, PUPIL ANATOMY PHYSL
[10]   Pupil size in refractive surgery [J].
Nixon, WS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1997, 23 (10) :1435-1436