Size-strain line-broadening analysis of the ceria round-robin sample

被引:422
作者
Balzar, D
Audebrand, N
Daymond, MR
Fitch, A
Hewat, A
Langford, JI
Le Bail, A
Louër, D
Masson, O
McCowan, CN
Popa, NC
Stephens, PW
Toby, BH
机构
[1] Univ Denver, Dept Phys & Astron, Denver, CO 80208 USA
[2] Natl Inst Stand & Technol, Boulder, CO 80305 USA
[3] Univ Rennes 1, Inst Chim, Chim Solide & Inorgan Mol Lab, CNRS,UMR 6511, F-35042 Rennes, France
[4] Rutherford Appleton Lab, ISIS Facil, Didcot OX11 0QX, Oxon, England
[5] European Synchrotron Radiat Facil, F-38043 Grenoble, France
[6] ILL Grenoble, F-38043 Grenoble, France
[7] Univ Birmingham, Birmingham, W Midlands, England
[8] Univ Maine, Lab Fluorures, CNRS, UMR 6010, F-72085 Le Mans 9, France
[9] Natl Inst Mat Phys, Bucharest, Romania
[10] SUNY Stony Brook, Dept Phys & Astron, Stony Brook, NY 11794 USA
[11] Natl Inst Stand & Technol, NCNR, Gaithersburg, MD 20899 USA
关键词
D O I
10.1107/S0021889804022551
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The results of both a line-broadening study on a ceria sample and a size - strain round robin on diffraction line-broadening methods, which was sponsored by the Commission on Powder Diffraction of the International Union of Crystallography, are presented. The sample was prepared by heating hydrated ceria at 923 K for 45 h. Another ceria sample was prepared to correct for the effects of instrumental broadening by annealing commercially obtained ceria at 1573 K for 3 h and slowly cooling it in the furnace. The diffraction measurements were carried out with two laboratory and two synchrotron X-ray sources, two constant-wavelength neutron and a time-of-flight (TOF) neutron source. Diffraction measurements were analyzed by three methods: the model assuming a lognormal size distribution of spherical crystallites, Warren-Averbach analysis and Rietveld refinement. The last two methods detected a relatively small strain in the sample, as opposed to the first method. Assuming a strain-free sample, the results from all three methods agree well. The average real crystallite size, on the assumption of a spherical crystallite shape, is 191 (5) Angstrom. The scatter of results given by different instruments is relatively small, although significantly larger than the estimated standard uncertainties. The Rietveld refinement results for this ceria sample indicate that the diffraction peaks can be successfully approximated with a pseudo-Voigt function. In a common approximation used in Rietveld refinement programs, this implies that the size-broadened profile cannot be approximated by a Lorentzian but by a full Voigt or pseudo-Voigt function. In the second part of this paper, the results of the round robin on the size - strain line-broadening analysis methods are presented, which was conducted through the participation of 18 groups from 12 countries. Participants have reported results obtained by analyzing data that were collected on the two ceria samples at seven instruments. The analysis of results received in terms of coherently diffracting, both volume-weighted and area-weighted apparent domain size are reported. Although there is a reasonable agreement, the reported results on the volume-weighted domain size show significantly higher scatter than those on the area-weighted domain size. This is most likely due to a significant number of results reporting a high value of strain. Most of those results were obtained by Rietveld refinement in which the Gaussian size parameter was not refined, thus erroneously assigning size-related broadening to other effects. A comparison of results with the average of the three-way comparative analysis from the first part shows a good agreement.
引用
收藏
页码:911 / 924
页数:14
相关论文
共 61 条
[1]  
[Anonymous], 2001, J APPL CRYSTALLOGR, DOI DOI 10.1107/S0021889801006094
[2]  
[Anonymous], NATL BUREAU STANDARD
[3]  
[Anonymous], 2004, Diffraction Analysis of the Microstructure of Materials
[4]  
[Anonymous], 1999, DEFECT MICROSTRUCTUR
[5]  
Armstrong N, 2004, DIFFRACTION ANALYSIS OF THE MICROSTRUCTURE OF MATERIALS, P187
[6]   An X-ray powder diffraction study of the microstructure and growth kinetics of nanoscale crystallites obtained from hydrated cerium oxides [J].
Audebrand, N ;
Auffrédic, JP ;
Louër, D .
CHEMISTRY OF MATERIALS, 2000, 12 (06) :1791-1799
[7]   VOIGT-FUNCTION MODELING IN FOURIER-ANALYSIS OF SIZE-BROADENED AND STRAIN-BROADENED X-RAY-DIFFRACTION PEAKS [J].
BALZAR, D ;
LEDBETTER, H .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1993, 26 (pt 1) :97-103
[8]   Elastic-strain tensor by Rietveld refinement of diffraction measurements [J].
Balzar, D ;
Von Dreele, RB ;
Bennett, K ;
Ledbetter, H .
JOURNAL OF APPLIED PHYSICS, 1998, 84 (09) :4822-4833
[9]   PROFILE FITTING OF X-RAY-DIFFRACTION LINES AND FOURIER-ANALYSIS OF BROADENING [J].
BALZAR, D .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1992, 25 :559-570
[10]  
Balzar D, 1996, J APPL CRYSTALLOGR, V29, P16, DOI 10.1107/S0021889895008478