Side-to-side sutureless vascular anastomosis with magnets

被引:61
作者
Erdmann, D
Sweis, R
Heitmann, C
Yasui, K
Olbrich, KC
Levin, LS
Sharkawy, AA
Klitzman, B
机构
[1] Duke Univ, Med Ctr, Kenan Plast Surg Res Labs, Durham, NC 27710 USA
[2] Duke Univ, Med Ctr, Kenan Plast Surg Res Labs, Div Plast Reconstruct Maxillofacial & Oral Surg, Durham, NC 27710 USA
[3] Duke Univ, Med Ctr, Dept Biomed Engn, Durham, NC 27710 USA
[4] Ventrica Inc, Fremont, CA USA
[5] Durham Vet Affairs Med Ctr, Durham, NC USA
关键词
D O I
10.1016/j.jvs.2004.05.026
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: Abbe and Payr introduced vascular techniques and devices to facilitate vessel anastomosis over a century ago. Obora published the idea of a sutureless vascular anastomosis with use of magnetic rings in 1978. The purpose of this study was to assess the performance of a new magnetic device to perform a side-to-side arteriovenous anastomosis in a dog model. Material and methods. Male fox hounds (25 kg) were treated preoperatively and daily postoperatively with clopidogrel bisulfate (Plavix) and aspirin. The femoral artery and vein were exposed unilaterally in 3 dogs and bilaterally in 4 dogs (n = 11 anastomoses). A 4-mm arteriotomy was performed, and 1 oval magnet 0.5 mm thick was inserted into the lumen of the artery and a second magnet was applied external to the artery, compressing and stabilizing the arterial wall to create a magnetic port. An identical venous magnetic port was created with another pair of oval magnets. When the 2 ports were allowed to approach each other, they self-aligned and magnetically coupled to complete the arteriovenous anastomosis. Patency was assessed for the first hour with direct observation, again after 9 weeks with duplex ultrasound scanning, and at 10 weeks under direct open observation. The anastomoses were explanted after 10 weeks. Hydrodynamic resistance was measured ex vivo on the final 8 anastomoses by measuring the pressure drop across an anastomosis with a known flow rate. Results: After implantation, very high flow created visible turbulence and palpable vibration. All 11 anastomoses were patent under direct observation and palpation. Ten of 11 anastomoses were clearly patent on duplex scans, and patency of 1 anastomosis was questionable. Hydrodynamic resistance averaged 0.73 +/- 0.33 mm Hg min/mL (mean +/- SEM). Conclusions. Vascular anastomoses performed with magnets demonstrated feasibility; exhibited 100% patency after 10 weeks in a dog arteriovenous shunt model; lacked apparent aneurysm or other potentially catastrophic failure; demonstrated remodeling of the vessel wall after several weeks to incorporate the magnets, making the magnetic force unnecessary; and warrants further study in vessels with different sizes, flow rates, and locations.
引用
收藏
页码:505 / 511
页数:7
相关论文
共 47 条
[1]
ABBE R, 1894, NY MED J, V59, P33
[2]
CLINICAL-EXPERIENCE WITH THE 3M MICROVASCULAR COUPLING ANASTOMOTIC DEVICE IN 100 FREE-TISSUE TRANSFERS [J].
AHN, CY ;
SHAW, WW ;
BERNS, S ;
MARKOWITZ, BL .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1994, 93 (07) :1481-1484
[3]
BERGGREN A, 1987, PLAST RECONSTR SURG, V80, P247
[4]
Blakemore AH, 1942, SURGERY, V12, P488
[5]
A NONSUTURE METHOD OF BLOOD VESSEL ANASTOMOSIS - EXPERIMENTAL AND CLINICAL STUDY [J].
BLAKEMORE, AH ;
LORD, JW .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1945, 127 (12) :685-691
[6]
SUTURELESS LASER-WELDED ANASTOMOSIS OF THE FEMORAL-ARTERY AND VEIN IN RATS USING CO2 AND ND-YAG LASERS [J].
BURGER, RA ;
GERHARZ, CD ;
DRAWS, J ;
ENGELMANN, UH ;
HOHENFELLNER, R .
JOURNAL OF RECONSTRUCTIVE MICROSURGERY, 1993, 9 (03) :213-218
[7]
Carrel A, 1907, B JOHNS HOPKINS HOSP, V18, P18
[8]
Carrel A., 1902, LYON MED, V98, P859
[9]
COBBETT JR, 1967, SURG CLIN N AM, V47, P521
[10]
AN ABSORBABLE ANASTOMOTIC DEVICE FOR MICROVASCULAR SURGERY - EXPERIMENTAL STUDIES [J].
DANIEL, RK ;
OLDING, M .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1984, 74 (03) :329-336