Fibrin sleeve stripping for salvage of failing hemodialysis catheters: Technique and initial results

被引:96
作者
Crain, MR
Mewissen, MW
Ostrowski, GJ
PazFumagalli, R
Beres, RA
Wertz, RA
机构
[1] Department of Radiology, Medical College of Wisconsin, Milwaukee, WI 53226
[2] Department of Radiology, St. Luke's Medical Center, Milwaukee, WI
关键词
catheters and catheterization; complications; technology; dialysis; shunts;
D O I
10.1148/radiology.198.1.8539402
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate percutaneous fibrin sleeve stripping (PFSS) to prolong functional patency in failing hemodialysis catheters. MATERIALS AND METHODS: Forty PFSS procedures were performed in 24 catheters in 23 consecutive patients with an inadequate blood flow rate (<200 ml/min) during hemodialysis. The fibrin sleeve was mechanically stripped off the shaft of the catheter with a snare introduced via the common femoral vein. Durability of PFSS was determined with life-table analysis. RESULTS: Median time from catheter placement to initial failure was 3.5 months (range, 5 days to 22 months). The technical success rate for PFSS was 100%; initial patency was restored in 39 of 40 procedures (98%), and no symptomatic pulmonary embolism occurred. Primary patency after single PFSS was 45% at 3 months and 28% at 6 months (median added patency, 2.8 months). Postprocedure secondary patency with multiple PFSS procedures was 83% at 3 months and 72% at 6 months (P = .01) (overall catheter patency, 90% at 6 months and 81% at 1 year [P < .001]). CONCLUSION: Multiple PFSS procedures can prolong patency in hemodialysis catheters with a fibrin sleeve.
引用
收藏
页码:41 / 44
页数:4
相关论文
共 14 条
[1]   DIAGNOSIS OF THROMBOSIS BY CATHETER PHLEBOGRAPHY AFTER PROLONGED CENTRAL VENOUS CATHETERIZATION [J].
BRISMAR, B ;
HARDSTEDT, C ;
JACOBSON, S .
ANNALS OF SURGERY, 1981, 194 (06) :779-783
[2]   WILL IATROGENIC PULMONARY EMBOLIZATION BE OUR PULMONARY EMBARRASSMENT [J].
DOLMATCH, BL ;
GRAY, RJ ;
HORTON, KM .
RADIOLOGY, 1994, 191 (03) :615-617
[3]   5 YEARS EXPERIENCE WITH THE QUINTON PERMCATH FOR VASCULAR ACCESS [J].
GIBSON, SP ;
MOSQUERA, D .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 1991, 6 (04) :269-274
[4]  
HAIRE WD, 1990, CANCER, V66, P2279, DOI 10.1002/1097-0142(19901201)66:11<2279::AID-CNCR2820661105>3.0.CO
[5]  
2-O
[6]   THROMBOSED CENTRAL VENOUS CATHETERS - RESTORING FUNCTION WITH 6-HOUR UROKINASE INFUSION AFTER FAILURE OF BOLUS UROKINASE [J].
HAIRE, WD ;
LIEBERMAN, RP .
JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1992, 16 (02) :129-132
[7]  
HOSHAL VL, 1971, ARCH SURG-CHICAGO, V102, P353
[8]  
KNELSON MH, 1993, JVIR, V4, P36
[9]   USE OF A SILICONE DUAL-LUMEN CATHETER WITH A DACRON CUFF AS A LONG-TERM VASCULAR ACCESS FOR HEMODIALYSIS-PATIENTS [J].
MOSS, AH ;
VASILAKIS, C ;
HOLLEY, JL ;
FOULKS, CJ ;
PILLAI, K ;
MCDOWELL, DE .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1990, 16 (03) :211-215
[10]   FATAL PULMONARY-EMBOLISM FOLLOWING REMOVAL OF A CENTRAL VENOUS CATHETER [J].
ROCKOFF, MA ;
GANG, DL ;
VACANTI, JP .
JOURNAL OF PEDIATRIC SURGERY, 1984, 19 (03) :307-309