Impact and prevention of far-field sensing in fallback mode switches

被引:22
作者
Bordacher, P
Cazeau, S
Graindorg, L [1 ]
Ritter, P
机构
[1] CA Boursidiere, ELA Med, F-92257 Le Plessis Robinson, France
[2] InParys, St Cloud, France
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2003年 / 26卷 / 01期
关键词
far-field signals; automatic mode switch; atrial arrhythmia; DDD pacing;
D O I
10.1046/j.1460-9592.2003.00017.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Far-field oversensing (FFOS) promoted by high atrial sensitivity and short atrial refractory periods induces false positive mode switches. We evaluated the incidence of ventricular FFOS in a population of DDD paced patients. Methods: One hundred thirty-seven patients (71 +/- 10 years, 76 men) implanted with a Talent DR pacemaker were studied. Before discharge, an analysis of internal data stored in the memories of the PM was performed by the specific software incorporated in the programmer in parallel with a 24-hour Holter recording. Data were validated by a panel of experts. One and 4 months follow-up was based only on the data stored in the PM memories. Results: Pacing indications were atrioventricular block (n = 75), sinus node dysfunction (n = 57), and other (n = 5). Sustained far-field oversensing was observed in 12/137 patients (9%). Out of a total of 3,511 triggered mode switch episodes, FFOS accounted for 20% and 7% of a 311 days cumulative time in mode switch. Inappropriate mode switch episodes induced by far-field were more numerous but shorter than episodes prompted by atrial arrhythmias. Atrial sensitivity was increased in eight patients, successfully in four. Reprogramming of the atrial refractory period (156 +/- 11 ms) was successful in five of six patients. Conclusions: A 9% rate of ventricular FFOS was observed in an unselected population, easily and automatically diagnosed using the internal memory function and the automatic analysis provided by the programmer. Prolongation of the atria] refractory period was more effective. than resetting of the atria] sensitivity in eliminating FFOS.
引用
收藏
页码:206 / 209
页数:4
相关论文
共 9 条
  • [1] Mode switch despite undersensing of atrial fibrillation in DDD pacing
    Bonnet, JL
    Brusseau, E
    Limousin, M
    Cazeau, S
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (11): : 1724 - 1728
  • [2] FAR-FIELD QRS COMPLEX SENSING VIA THE ATRIAL PACEMAKER LEAD .2. PREVALENCE, CLINICAL-SIGNIFICANCE AND POSSIBILITY OF INTRAOPERATIVE PREDICTION IN DDD PACING
    BRANDT, J
    FAHRAEUS, T
    SCHULLER, H
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (11): : 1540 - 1544
  • [3] FAR-FIELD QRS COMPLEX SENSING VIA THE ATRIAL PACEMAKER LEAD .1. MECHANISM, CONSEQUENCES, DIFFERENTIAL-DIAGNOSIS AND COUNTERMEASURES IN AAI AND VDD/DDD PACING
    BRANDT, J
    FAHRAEUS, T
    SCHULLER, H
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (10): : 1432 - 1438
  • [4] DIAGNOSIS OF ATRIAL ARRHYTHMIAS USING THE HOLTER FUNCTION OF A NEW DDD PACEMAKER
    CAZEAU, S
    RITTER, P
    NITZSCHE, R
    LIMOUSIN, M
    MUGICA, J
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (11): : 2106 - 2113
  • [5] Prevalence of supraventricular arrhythmias from the automated analysis of data stored in the DDD pacemakers of 617 patients: The AIDA study
    Defaye, P
    Dournaux, F
    Mouton, E
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (01): : 250 - 255
  • [6] Garrigue S, 1996, ARCH MAL COEUR VAISS, V89, P873
  • [7] GEROUX L, 1999, HERZSCHRITTMACHER TH, V1, P15
  • [8] Analysis of mode switching algorithms in dual chamber pacemakers
    Israel, CW
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (03): : 380 - 393
  • [9] Value of automatic processing and reliability of stored data in an implanted pacemaker: Initial results in 59 patients
    Limousin, M
    Geroux, L
    Nitzsche, R
    Cazeau, S
    Pioger, G
    Victor, J
    Poty, H
    Puglisi, A
    Ricci, R
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (12): : 2893 - 2898