Direct determination of copper and lead in sewage sludge by solid sampling-graphite furnace atomic absorption spectrometry - study of the interference reduction in the gaseous phase working in non-stop flow conditions

被引:21
作者
Belarra, MA [1 ]
Crespo, C [1 ]
Resano, M [1 ]
Castillo, JR [1 ]
机构
[1] Univ Zaragoza, Dept Analyt Chem, E-50009 Zaragoza, Spain
关键词
solid sampling; graphite furnace-atomic absorption spectrometry; sewage sludge; lead; copper;
D O I
10.1016/S0584-8547(00)00217-2
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Graphite furnace atomic absorption spectrometry is most useful for the determination of metals in solid samples when samples with a slow or complicated dissolution process are used. Its application to inorganic matrixes (especially geological material), therefore, appears to be a field of great interest. However, most of the papers published to date deal with organic samples, In the present paper two different strategies for the direct determination of metals in inorganic samples are proposed depending on the relationship between the analyte atomization temperature and the vaporization temperature of the matrix. For the more complicated case where both temperatures are similar, working in non-stop flow conditions is proposed because it permits a considerable reduction of interferences in the gas phase. This way the determination of lead and copper in a sewage sludge sample was carried out. The results can be considered as satisfactory with regard to both accuracy and precision (R.S.D. of 7.8% and 5.7%, for Pb and Cu, respectively), as they are similar to previous ones obtained for mainly organic less problematic samples. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:865 / 874
页数:10
相关论文
共 26 条
[1]   DIRECT DETERMINATION OF COPPER AT TRACE LEVELS IN SOLID SAMPLES OF ANIMAL FEED USING ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY [J].
ANZANO, JM ;
MARTINEZGARBAYO, MP ;
BELARRA, MA ;
CASTILLO, JR .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (02) :125-128
[2]   ON THE DIRECT ANALYSIS OF SOLID SAMPLES BY GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
BAXTER, DC ;
FRECH, W .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 337 (03) :253-263
[3]   RAPID-DETERMINATION OF LEAD BY ANALYSIS OF SOLID SAMPLES USING GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
BELARRA, MA ;
LAVILLA, I ;
ANZANO, JM ;
CASTILLO, JR .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (07) :1075-1078
[4]   Graphite-furnace atomic absorption spectrometric method for direct determination of iron and zinc in solid rice samples [J].
Belarra, MA ;
MartinezGarbayo, MP ;
Anzano, JM ;
Castillo, JR .
ANALYTICAL SCIENCES, 1996, 12 (03) :483-488
[5]   Direct determination of metals in solid samples by graphite-furnace atomic absorption spectrometry: Does sample mass influence the analytical results? [J].
Belarra, MA ;
Crespo, C ;
Martinez-Garbayo, MP ;
Castillo, JR .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (12) :1855-1860
[6]   Theoretical evaluation of solid sampling electrothermal atomic absorption spectrometry for screening purposes [J].
Belarra, MA ;
Resano, M ;
Castillo, JR .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (04) :547-552
[7]   Discrimination of the causes of imprecision in the direct determination of metals in organic solid samples by electrothermal atomization atomic absorption spectrometry [J].
Belarra, MA ;
Resano, M ;
Castillo, JR .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (05) :489-494
[8]   Expanding the working concentration range in graphite furnace atomic absorption spectrometry. Effect of non-stop flow on the determination of tin [J].
Belarra, MA ;
Resano, M ;
Castillo, JR .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (08) :1223-1227
[9]  
BELARRA MA, 1999, ACTA PART B, V54, P787
[10]  
DEKERSABIEC AM, 1987, FRESEN Z ANAL CHEM, V328, P342