Implementation of a Closed-Loop Reporting System for Critical Values and Clinical Communication in Compliance with Goals of The Joint Commission

被引:47
作者
Parl, Fritz F. [1 ]
O'Leary, Mandy F.
Kaiser, Allen B. [2 ]
Paulett, John M. [3 ]
Statnikova, Kristina [3 ]
Shultz, Edward K. [3 ]
机构
[1] Vanderbilt Univ, Med Ctr, Dept Pathol, Clin Chem Lab, Nashville, TN 37232 USA
[2] Vanderbilt Univ, Med Ctr, Dept Internal Med, Nashville, TN 37232 USA
[3] Vanderbilt Univ, Med Ctr, Informat Ctr, Nashville, TN 37232 USA
关键词
PATHOLOGISTS Q-PROBES; NOTIFICATION;
D O I
10.1373/clinchem.2009.135376
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BACKGROUND: Current practices of reporting critical laboratory values make it challenging to measure and assess the timeliness of receipt by the treating physician as required by The Joint Commission's 2008 National Patient Safety Goals. METHODS: A multidisciplinary team of laboratorians, clinicians, and information technology experts developed an electronic ALERTS system that reports critical values via the laboratory and hospital information systems to alphanumeric pagers of clinicians and ensures failsafe notification, instant documentation, automatic tracking, escalation, and reporting of critical value alerts. A method for automated acknowledgment of message receipt was incorporated into the system design. RESULTS: The ALERTS system has been applied to inpatients and eliminated approximately 9000 phone calls a year made by medical technologists. Although a small number of phone calls were still made as a result of pages not acknowledged by clinicians within 10 min, they were made by telephone operators, who either contacted the same physician who was initially paged by the automated system or identified and contacted alternate physicians or the patient's nurse. Overall, documentation of physician acknowledgment of receipt in the electronic medical record increased to 95% of critical values over 9 months, while the median time decreased to <3 min. CONCLUSIONS: We improved laboratory efficiency and physician communication by developing an electronic system for reporting of critical values that is in compliance with The joint Commission's goals. (C) 2009 American Association for Clinical Chemistry
引用
收藏
页码:417 / 423
页数:7
相关论文
共 16 条
[1]   Improving patient safety by repeating (read-back) telephone reports of critical information [J].
Barenfanger, J ;
Sautter, RL ;
Lang, DL ;
Collins, SM ;
Hacek, DM ;
Peterson, LR .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2004, 121 (06) :801-803
[2]  
Dighe AS, 2008, ARCH PATHOL LAB MED, V132, P1666, DOI 10.1043/1543-2165(2008)132[1666:SOCVRA]2.0.CO
[3]  
2
[4]   Analysis of laboratory critical value reporting at a large academic medical center [J].
Dighe, AS ;
Rao, A ;
Coakley, AB ;
Lewandrowski, KB .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2006, 125 (05) :758-764
[5]   Communicating Critical Test Results: Safe Practice Recommendations [J].
Hanna, Doris ;
Griswold, Paula ;
Leape, Lucian L. ;
Bates, David W. .
JOINT COMMISSION JOURNAL ON QUALITY AND PATIENT SAFETY, 2005, 31 (02) :68-80
[6]   Critical value called, read-back obtained [J].
Haverstick, DM .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2004, 121 (06) :790-791
[7]  
Howanitz PJ, 2002, ARCH PATHOL LAB MED, V126, P663
[8]  
Joint Commission, NAT PAT SAF GOALS 20
[9]  
Kost Gerlad J, 2004, MLO Med Lab Obs, V36, P6
[10]   Improving response to critical laboratory results with automation: Results of a randomized controlled trial [J].
Kuperman, GJ ;
Teich, JM ;
Tanasijevic, MJ ;
Ma'Luf, N ;
Rittenberg, E ;
Jha, A ;
Fiskio, J ;
Winkelman, J ;
Bates, DW .
JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 1999, 6 (06) :512-522