Particulate matter in the underground of Stockholm

被引:221
作者
Johansson, C
Johansson, PÅ
机构
[1] Environm & Hlth Protect Adm, S-10064 Stockholm, Sweden
[2] Stockholm Univ, Inst Appl Environm Res, Air Pollut Lab, S-10691 Stockholm, Sweden
关键词
PM10; PM2.5; population exposure; underground rail; TSP; indoor levels; transport microenvironment;
D O I
10.1016/S1352-2310(02)00833-6
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The concentrations of PM10 and PM2.5 were measured during 2 weeks at an underground station in central Stockholm. The instrument, an automatic TEOM monitor (Tapered Element Oscillating Microbalance), was placed on the platform in the centre of the station. During weekdays between 7 a.m. and 7 p.m. the average PM10 and PM12.5 concentrations were 470 and 260 mug/m(3), respectively. These levels are a factor 5 and 10 times higher than the corresponding values measured in one of the busiest streets in central Stockholm. The concentrations in the underground followed closely the train traffic intensity. The levels were very similar from one day to the next. During Saturdays and Sundays the levels decreased slightly due to less frequent train passages. Additional measurements were performed right after the tunnel had been washed. Tunnel walls and railway tracks between the platforms of the underground system were washed using water. Only a slight reduction of the PM10 levels (approximately 13%) could be observed during a few days after the water treatment. For PM12.5 the reduction was even less, about 10% lower levels could be seen. This might indicate that particles from tunnel walls and tracks make only a minor contribution to the observed levels. These results confirm earlier unpublished measurements showing high levels of PM in the underground of Stockholm. Substantially, elevated particle exposure levels have also been reported in several earlier studies in the underground
引用
收藏
页码:3 / 9
页数:7
相关论文
共 10 条
[1]   Fine particle (PM2.5) personal exposure levels in transport microenvironments, London, UK [J].
Adams, HS ;
Nieuwenhuijsen, MJ ;
Colvile, RN ;
McMullen, MAS ;
Khandelwal, P .
SCIENCE OF THE TOTAL ENVIRONMENT, 2001, 279 (1-3) :29-44
[2]  
AXELSSON G, 1997, DUST MEASUREMENTS UN
[3]  
COLMSJO A, 1990, POLYCYCLIC AROMATIC
[4]   Free radical activity of PM10: Iron-mediated generation of hydroxyl radicals [J].
Donaldson, K ;
Brown, DM ;
Mitchell, C ;
Dineva, M ;
Beswick, PH ;
Gilmour, P ;
MacNee, W .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1997, 105 :1285-1289
[5]  
GILMOUR P, 1997, ANN OCCUP HYG, V41, P32
[6]   In vivo and in vitro proinflammatory effects of particulate air pollution (PM10) [J].
Li, XY ;
Gilmour, PS ;
Donaldson, K ;
MacNee, W .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1997, 105 :1279-1283
[7]   Personal exposures to airborne metals in London taxi drivers and office workers in 1995 and 1996 [J].
Pfeifer, GD ;
Harrison, RM ;
Lynam, DR .
SCIENCE OF THE TOTAL ENVIRONMENT, 1999, 235 (1-3) :253-260
[8]  
Priest N.D., 1998, DUST LEVELS LONDON U
[9]   Characterisation of airborne particles in London by computer-controlled scanning electron microscopy [J].
Sitzmann, B ;
Kendall, M ;
Watt, J ;
Williams, I .
SCIENCE OF THE TOTAL ENVIRONMENT, 1999, 241 (1-3) :63-73
[10]  
WESTERLUND KG, 1983, PRESENTATION RESULTS