Dosimetry for a study of low-dose radiation cataracts among chernobyl clean-up workers

被引:36
作者
Chumak, V. V.
Worgul, B. V.
Kundiyev, Y. I.
Sergiyenko, N. M.
Vitte, P. M.
Medvedovsky, C.
Bakhanova, E. V.
Junk, A. K.
Kyrychenko, O. Y.
Musijachenko, N. V.
Sholom, S. V.
Shylo, S. A.
Vitte, O. P.
Xu, S.
Xue, X.
Shore, R. E.
机构
[1] NYU, Sch Med, New York, NY 10016 USA
[2] AMS Ukraine, Sci Ctr Radiat Med, UA-04050 Kiev, Ukraine
[3] Columbia Univ, Eye Radiat & Environm Res Lab, New York, NY 10032 USA
[4] AMS Ukraine, Inst Occupat Hlth, UA-01033 Kiev, Ukraine
[5] Natl Med Acad Postgrad Educ, UA-04112 Kiev, Ukraine
[6] Univ Miami, Bascom Palmer Eye Inst, Miami, FL 33136 USA
[7] Albert Einstein Coll Med, Bronx, NY 10461 USA
关键词
D O I
10.1667/RR0302.1
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
A cohort of 8,607 Ukrainian Chernobyl clean-up workers during 1986-1987 was formed to study cataract formation after ionizing radiation exposure. Study eligibility required the availability of sufficient exposure information to permit the reconstruction of doses to the lens of the eye. Eligible groups included civilian workers, such as those who built the "sarcophagus" over the reactor, Chernobyl Nuclear Power Plant Workers, and military reservists who were conscripted for clean-up work. Many of the official doses for workers were estimates, because only a minority wore radiation badges. For 106 military workers, electron paramagnetic resonance (EPR) measurements of extracted teeth were compared with the recorded doses as the basis to adjust the recorded gamma-ray doses and provide estimates of uncertainties. Beta-particle doses to the lens were estimated with an algorithm devised to take into account the nature and location of Chernobyl work, time since the accident, and protective measures taken. A Monte Carlo routine generated 500 random estimates for each individual from the uncertainty distributions of the gamma-ray dose and of the ratio of beta-particle to gamma-ray doses. The geometric mean of the 500 combined beta-particle and gamma-ray dose estimates for each individual was used in the data analyses. The median estimated lens dose for the cohort was 123 mGy, while 4.4% received > 500 mGy. (c) 2007 by Radiation Research Society.
引用
收藏
页码:606 / 614
页数:9
相关论文
共 20 条
  • [1] BRIESMEISTER JF, 1997, LA126257
  • [2] CHARLES M, 1999, OCULAR RAD RISK ASSE, P110
  • [3] The first international intercomparison of EPR-dosimetry with teeth: First results
    Chumak, V
    Bailiff, I
    Baran, N
    Bugai, A
    Dubovsky, S
    Fedosov, I
    Finin, V
    Haskell, E
    Hayes, R
    Ivannikov, A
    Kenner, G
    Kirillov, V
    Khamidova, L
    Kolesnik, S
    Liidja, G
    Likhtarev, I
    Lippmaa, E
    Maksimenko, V
    Meijer, A
    Minenko, V
    Pasalskaya, L
    Past, J
    Puskar, J
    Radchuk, V
    Sholom, S
    Skvortzov, V
    Stepanenko, V
    Vaher, U
    Wieser, A
    [J]. APPLIED RADIATION AND ISOTOPES, 1996, 47 (11-12) : 1281 - 1286
  • [4] Application of high precision EPR dosimetry with teeth for reconstruction of doses to Chernobyl populations
    Chumak, V
    Sholom, S
    Pasalskaya, L
    [J]. RADIATION PROTECTION DOSIMETRY, 1999, 84 (1-4) : 515 - 520
  • [5] CHUMAK V, 1998, P 1998 ANS RAD PROT, P545
  • [6] High precision EPR dosimetry as a reference tool for validation of other techniques
    Chumak, VV
    Sholom, SV
    Bakhanova, EV
    Pasalskaya, LF
    Musijachenko, AV
    [J]. APPLIED RADIATION AND ISOTOPES, 2005, 62 (02) : 141 - 146
  • [7] CHUMAK VV, 2000, P 40 INT C INT RAD P
  • [8] ICRU, 1997, DOS EXT BET RAYS RAD
  • [9] Il'in L. A., 1995, Radiatsionnaya Biologiya Radioekologiya, V35, P803
  • [10] KUMAZAWA S, 1984, EPA520184005