Development of a multifrequency conductance catheter-based system to determine LV function in mice

被引:44
作者
Feldman, MD
Mao, Y
Valvano, JW
Pearce, JA
Freeman, GL
机构
[1] Univ Texas, Hlth Sci Ctr, San Antonio, TX 78284 USA
[2] Univ Texas, Biomed Engn Program, Austin, TX 78712 USA
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 2000年 / 279卷 / 03期
关键词
transgenic mouse; pressure-volume analysis; myocardial resistivity; left ventricular function;
D O I
10.1152/ajpheart.2000.279.3.H1411
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Transgenic mice offer a valuable way to relate gene products to phenotype, but the ability to assess the cardiovascular phenotype with pressure-volume analysis has lagged. Conductance measurement offers a method to generate an instantaneous left ventricular (LV) volume signal in the mouse but has been limited by the volume signal being a combination of blood and LV muscle. We hypothesized that by developing a mouse conductance system that operates at several simultaneous frequencies, we could identify and correct for the myocardial contribution to the instantaneous volume signal. This hypothesis is based on the assumption that mouse myocardial conductivity will vary with frequency, whereas mouse blood conductivity will not. Consistent with this hypothesis, we demonstrated that at higher excitation frequency, greater end-diastolic and end-systolic conductance are detected, as well as a smaller difference between the two. We then empirically solved for LV blood volume using two frequencies. We combined measured resistivity of mouse myocardium with an analytic approach and extracted an estimate of LV blood volume from the raw conductance signal. Development of a multifrequency catheter-based system to determine LV function could be a tool to assess cardiovascular phenotype in transgenic mice.
引用
收藏
页码:H1411 / H1420
页数:10
相关论文
共 33 条
  • [1] CONTINUOUS MEASUREMENT OF LEFT-VENTRICULAR VOLUME IN ANIMALS AND HUMANS BY CONDUCTANCE CATHETER
    BAAN, J
    VANDERVELDE, ET
    DEBRUIN, HG
    SMEENK, GJ
    KOOPS, J
    VANDIJK, AD
    TEMMERMAN, D
    SENDEN, J
    BUIS, B
    [J]. CIRCULATION, 1984, 70 (05) : 812 - 823
  • [2] LEFT-VENTRICULAR VOLUME MEASUREMENT BY CONDUCTANCE CATHETER IN INTACT DOGS - PARALLEL CONDUCTANCE VOLUME DEPENDS ON LEFT-VENTRICULAR SIZE
    BOLTWOOD, CM
    APPLEYARD, RF
    GLANTZ, SA
    [J]. CIRCULATION, 1989, 80 (05) : 1360 - 1377
  • [3] ACCURACY OF VOLUME MEASUREMENT BY CONDUCTANCE CATHETER IN ISOLATED, EJECTING CANINE HEARTS
    BURKHOFF, D
    VANDERVELDE, E
    KASS, D
    BAAN, J
    MAUGHAN, WL
    SAGAWA, K
    [J]. CIRCULATION, 1985, 72 (02) : 440 - 447
  • [4] Cabreriza SE, 1997, ASAIO J, V43, pM509
  • [5] THE CONDUCTANCE VOLUME CATHETER TECHNIQUE FOR MEASUREMENT OF LEFT-VENTRICULAR VOLUME IN YOUNG PIGLETS
    CASSIDY, SC
    TEITEL, DF
    [J]. PEDIATRIC RESEARCH, 1992, 31 (01) : 85 - 90
  • [6] Physiological assessment of complex cardiac phenotypes in genetically engineered mice
    Christensen, G
    Wang, YB
    Chien, KR
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1997, 272 (06): : H2513 - H2524
  • [7] CONOVER WJ, 1971, PRACTICAL NONPARAMET, P271
  • [8] ANISOTROPY IN THE DIELECTRIC-PROPERTIES OF SKELETAL-MUSCLE
    EPSTEIN, BR
    FOSTER, KR
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1983, 21 (01) : 51 - 55
  • [9] MYOCARDIAL ELECTRICAL-IMPEDANCE MAPPING OF ISCHEMIC SHEEP HEARTS AND HEALING ANEURYSMS
    FALLERT, MA
    MIROTZNIK, MS
    DOWNING, SW
    SAVAGE, EB
    FOSTER, KR
    JOSEPHSON, ME
    BOGEN, DK
    [J]. CIRCULATION, 1993, 87 (01) : 199 - 207
  • [10] Feldman MD, 1999, CIRCULATION, V100, P759