Optimization of a bent perfect Si(111) monochromator at a small take-off angle for use in a stress instrument

被引:21
作者
Seong, Baek-Seok [1 ]
Em, Vyacheslav [1 ]
Mikula, Pavol [2 ,3 ]
Saroun, Jan [2 ,3 ]
Kang, Mi-Hyun [1 ,4 ]
机构
[1] Korea Atom Energy Res Inst, Div Neutron Sci, Daedok 1045, South Korea
[2] Res Ctr Rez Ltd, Rez, Czech Republic
[3] Nucl Phys Inst ASCR, VVI, Rez, Czech Republic
[4] Chungnam Natl Univ, Taejon 305764, South Korea
关键词
SENSITIVE NEUTRON DETECTOR; DIFFRACTION; OPTICS;
D O I
10.1107/S0021889810008551
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The reflectivity and resolution properties of focusing cylindrically bent perfect crystal Si(111) monochromators of different diffraction geometries were tested with the aim of evaluating their possible use in a stress instrument with an unusually small take-off angle (2 theta(M) similar or equal to 30 degrees). The experiments showed that an Si crystal with reflecting planes (111) in the symmetric diffraction geometry provides a maximum figure of merit for accuracy in the peak position that is comparable to that achieved previously from an optimized Si(220) monochromator at 2 theta(M) similar or equal to 55 degrees
引用
收藏
页码:654 / 658
页数:5
相关论文
共 23 条
[1]  
Bacon G. E., 1975, NEUTRON DIFFRACTION
[2]   CHOICE OF COLLIMATORS FOR A CRYSTAL SPECTROMETER FOR NEUTRON DIFFRACTION [J].
CAGLIOTI, G ;
PAOLETTI, A ;
RICCI, FP .
NUCLEAR INSTRUMENTS & METHODS, 1958, 3 (04) :223-228
[3]  
Caglioti G., 1970, Thermal neutron diffraction, P14
[4]  
Hutchings MT., 2005, INTRO CHARACTERIZATI
[5]   Optimizing the neutron diffractometers configurations [J].
Ionita, I. .
PHYSICA B-CONDENSED MATTER, 2004, 350 (1-3) :E675-E678
[6]   Design for a focusing high-resolution neutron crystal diffractometer [J].
Ionita, I ;
Stoica, AD ;
Popovici, M ;
Popa, NC .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 431 (03) :509-520
[7]   An optimum design for a time-of-flight neutron diffractometer for measuring engineering stresses [J].
Johnson, MW ;
Daymond, MR .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2002, 35 :49-57
[8]   COMPARATIVE TESTS OF NEUTRON MONOCHROMATORS USING ELASTICALLY BENT SILICON AND MOSAIC CRYSTALS [J].
KULDA, J ;
WAGNER, V ;
MIKULA, P ;
SAROUN, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 338 (01) :60-64
[9]   The residual stress instrument with optimized Si(220) monochromator and position-sensitive detector at HANARO [J].
Lee, CH ;
Moon, MK ;
Em, VT ;
Choi, YH ;
Cheon, JK ;
Nam, UW ;
Kong, KN .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 545 (1-2) :480-489
[10]   BENT PERFECT CRYSTALS IN ASYMMETRIC DIFFRACTION GEOMETRY IN NEUTRON-SCATTERING EXPERIMENTS [J].
MIKULA, P ;
KULDA, J ;
LUKAS, P ;
VRANA, M ;
WAGNER, V .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 338 (01) :18-26