Analytical validation of the BEM - application of the BEM to the electrocardiographic forward and inverse problem

被引:25
作者
Fischer, G
Tilg, B
Wach, P
Lafer, G
Rucker, W
机构
[1] Graz Tech Univ, Inst Biomed Engn, Dept Biophys, A-8010 Graz, Austria
[2] Univ Stuttgart, Inst Theory Elect Engn, D-70569 Stuttgart, Germany
基金
奥地利科学基金会;
关键词
transmembrane potential; electrocardiographic forward problem; inverse problem;
D O I
10.1016/S0169-2607(97)00060-6
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The objective of this study is to analytically validate a boundary element (BE) formulation for the relationship between the transmembrane potential on the heart's surface and the potential on the body surface applying a concentric spherical test geometry. The relative difference (reldif) between the potential on the outer sphere of the test geometry computed analytically and numerically is determined by 3.59% for the coarse discretization (48 BEs) and by 0.46% in the case of the finer subdivision (192 BEs). In the inverse problem, the transmembrane potential on the inner sphere is estimated numerically from the electric potential on the outer sphere by using a minimum-norm least-square approach. The relative differences found are 20.2% when no measurement noise is added and 26.4% in the presence of 2% additional Gaussian noise. The BE formulation is also applied to real world data for solving the electrocardiographic inverse problem. A normal volunteer's inhomogeneous thorax (outer thorax surface, surfaces of the lungs, epicardial heart surface) is modelled by 424 BEs. The same inverse method is then applied in order to reconstruct the transmembrane potential on the epicardium from the measured body surface potential (BSP) data during normal ventricular depolarisation. (C) 1998 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:99 / 106
页数:8
相关论文
共 15 条
[1]   BOUNDARY ELEMENT SOLUTION OF BIOMAGNETIC PROBLEMS [J].
BOMMEL, FR ;
ROCKELEIN, R ;
URANKAR, L .
IEEE TRANSACTIONS ON MAGNETICS, 1993, 29 (02) :1395-1398
[2]   TOTAL EXCITATION OF ISOLATED HUMAN HEART [J].
DURRER, D ;
VANDAM, RT ;
FREUD, GE ;
JANSE, MJ ;
MEIJLER, FL ;
ARZBAECHER, RC .
CIRCULATION, 1970, 41 (06) :899-+
[3]   A COMPLETE LINEAR DISCRETIZATION FOR CALCULATING THE MAGNETIC-FIELD USING THE BOUNDARY-ELEMENT METHOD [J].
FERGUSON, AS ;
ZHANG, X ;
STROINK, G .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1994, 41 (05) :455-460
[4]  
FISCHER G, 1997, BIOMED TECHNIK GR S1, V42, P103
[5]   ON BIOELECTRIC POTENTIALS IN AN INHOMOGENEOUS VOLUME CONDUCTOR [J].
GESELOWI.DB .
BIOPHYSICAL JOURNAL, 1967, 7 (01) :1-&
[6]  
Greensite Fred, 1994, Critical Reviews in Biomedical Engineering, V22, P347
[7]  
HUISKAMP G, 1995, P 17 INT C IEEE ENG
[8]   MAGNETOCARDIOGRAPHIC FUNCTIONAL LOCALIZATION USING A CURRENT DIPOLE IN A REALISTIC TORSO [J].
NENONEN, J ;
PURCELL, CJ ;
HORACEK, BM ;
STROINK, G ;
KATILA, T .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1991, 38 (07) :658-664
[9]   THE USE OF TEMPORAL INFORMATION IN THE REGULARIZATION OF THE INVERSE PROBLEM OF ELECTROCARDIOGRAPHY [J].
OSTER, HS ;
RUDY, Y .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (01) :65-75
[10]  
RUCKER W, 1987, THESIS TU GRAZ