Biological assessment of the bone-screw interface after insertion of uncoated and hydroxyapatite-coated pedicular screws in the osteopenic sheep

被引:56
作者
Fini, M
Giavaresi, G
Greggi, T
Martini, L
Aldini, NN
Parisini, P
Giardino, R
机构
[1] Rizzoli Orthopaed Inst, Dept Expt Surg, Res Inst Codivilla Putti, I-40136 Bologna, Italy
[2] Rizzoli Orthopaed Inst, Dept Spinal Surg, I-40136 Bologna, Italy
[3] Univ Bologna, Fac Med, Chair Surg Pathophysiol, I-40100 Bologna, Italy
关键词
osteoporosis; pedicular fixation; hydroxyapatite; sheep; bone healing;
D O I
10.1002/jbm.a.10605
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
The sheep seems to be a promising model of osteoporosis and biomaterial osteointegration in osteopenic bone. The long-term ovariectomized sheep model was used for the biological investigation of bone healing around uncoated and hydroxyapatite (HA)-coated pedicle screws in osteopenic bone. Four sheep were ovariectomized and four sheep were sham-operated. Twenty-four months after surgery, the animals were implanted with uncoated and HA-coated stainless steel screws in the lumbar vertebral pedicles. Four months later, bone-to-implant contact, bone ingrowth, and bone hardness were measured around screws. Uncoated stainless steel presented significantly (p < 0.0005) lower bone-to-implant contact in healthy and osteopenic bone compared with HA-coated stainless steel. HA significantly improved bone ingrowth in healthy bone (p < 0.05) compared with uncoated stainless steel. Osteopenia significantly (p < 0.05) reduced the area of bone ingrowth around the screw threads for both types of implants. In the inner thread area, bone microhardness significantly increased (p < 0.05) in HA-coated surface versus uncoated for healthy and osteopenic bone. HA coating significantly enhances bone-to-implant contact also in osteopenic bone in comparison with uncoated stainless steel surfaces. Bone ingrowth and mineralization are ameliorated by the osteoconductive HA coating. However, osteopenia seems to greatly influence bone ingrowth processes around the implanted screws regardless of the characteristics of the material surface. (C) 2003 Wiley Periodicals, Inc.
引用
收藏
页码:176 / 183
页数:8
相关论文
共 37 条
[1]
ALBREKTSSON T, 1991, BONE-BIOMATERIAL INTERFACE, P357
[2]
ALDINI NN, IN PRESS J ORTHOP RE
[3]
An YH, 1998, ANIMAL MODELS IN ORTHOPAEDIC RESEARCH, P85
[4]
HEALING COMPLICATIONS AFTER INTERNAL-FIXATION OF TROCHANTERIC HIP-FRACTURES - THE PROGNOSTIC VALUE OF OSTEOPOROSIS [J].
BARRIOS, C ;
BROSTROM, LA ;
STARK, A ;
WALHEIM, G .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1993, 7 (05) :438-442
[5]
BELLINO FL, 1998, LAB ANIM SCI, V48, P623
[6]
Factors in implant integration failure after bone grafting - An osteometric and endocrinologic matched analysis [J].
Blomqvist, JE ;
Alberius, P ;
Isaksson, S ;
Linde, A ;
Hansson, BG .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1996, 25 (01) :63-68
[7]
Evaluation of systemic metal diffusion after spinal pedicular fixation with titanium alloy and stainless steel system: a 36-month experimental study in sheep [J].
Brayda-Bruno, M ;
Fini, M ;
Pierini, G ;
Giavaresi, G ;
Rocca, M ;
Giardino, R .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2001, 24 (01) :41-49
[8]
Bone regeneration by implantation of purified, culture-expanded human mesenchymal stem cells [J].
Bruder, SP ;
Kurth, AA ;
Shea, M ;
Hayes, WC ;
Jaiswal, N ;
Kadiyala, S .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1998, 16 (02) :155-162
[9]
Chang YL, 1999, J ORAL MAXIL SURG, V57, P1096
[10]
A MECHANICAL INVESTIGATION OF FLUORAPATITE, MAGNESIUMWHITLOCKITE, AND HYDROXYLAPATITE PLASMA-SPRAYED COATINGS IN GOATS [J].
DHERT, WJA ;
KLEIN, CPAT ;
WOLKE, JGC ;
VANDERVELDE, EA ;
DEGROOT, K ;
ROZING, PM .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1991, 25 (10) :1183-1200