Aims: To describe the optics of in vivo confocal microscopy, its advantages over previous methods, and to summarise the literature that arose from its use for the observation of the human cornea. A critical review of the clinical usefulness of this new technology for the corneal examination is undertaken. Methods: Confocal microscopes obtain increased resolution by limiting the illumination and observation systems to a single point. Rapid scanning is used to reconstruct a full field of view and allows for "real time" viewing. Results: Coronal sections of the in situ epithelium, Bowman's membrane, stroma, and endothelium can be visualised at a resolution of 1-2 mum. A backscattered light intensity curve allows objective measurements of sublayer thickness and corneal haze to be taken. In vivo confocal microscopy is therefore particularly useful in the areas of infective keratitis, corneal dystrophies, refractive surgery, and contact lens wear, where it aids in differential diagnosis and detection of subtle short and long term changes. Real time endothelial cell assessment can also be performed. Conclusion: Because of their ability to visualise living tissue at cellular levels, confocal microscopes have proved useful additions to the current clinical tools.
引用
收藏
页码:225 / 236
页数:12
相关论文
共 176 条
[1]  
Alió JL, 2001, J REFRACT SURG, V17, P503
[2]  
Andrade H A, 1990, Refract Corneal Surg, V6, P346
[3]  
AURAN JD, 1995, OPHTHALMOLOGY, V102, P33
[4]   IN-VIVO SCANNING SLIT CONFOCAL MICROSCOPY OF ACANTHAMOEBA-KERATITIS - A CASE-REPORT [J].
AURAN, JD ;
STARR, MB ;
KOESTER, CJ ;
LABOMBARDI, VJ .
CORNEA, 1994, 13 (02) :183-185
[5]  
Auzerie O, 2002, J FR OPHTALMOL, V25, P9
[6]   Central corneal thickness measurement with a retinal optical coherence tomography device versus standard ultrasonic pachymetry [J].
Bechmann, M ;
Thiel, MJ ;
Neubauer, AS ;
Ullrich, S ;
Ludwig, K ;
Kenyon, KR ;
Ulbig, MW .
CORNEA, 2001, 20 (01) :50-54
[7]   Depth and age-dependent distribution of keratocytes in healthy human corneas - A study using scanning-slit confocal microscopy in vivo [J].
Berlau, J ;
Becker, HH ;
Stave, J ;
Oriwol, C ;
Guthoff, RF .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (04) :611-616
[8]   QUANTIFICATION OF REAL-TIME CONFOCAL IMAGES OF THE HUMAN CORNEA [J].
BEUERMAN, RW ;
LAIRD, JA ;
KAUFMAN, SC ;
KAUFMAN, HE .
JOURNAL OF NEUROSCIENCE METHODS, 1994, 54 (02) :197-203
[9]   Confocal microscopy of the cornea [J].
Böhnke, M ;
Masters, BR .
PROGRESS IN RETINAL AND EYE RESEARCH, 1999, 18 (05) :553-628
[10]   Confocal microscopy reveals persisting stromal changes after myopic photorefractive keratectomy in zero haze corneas [J].
Böhnke, M ;
Thaer, A ;
Schipper, I .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1998, 82 (12) :1393-1400