The efficacy of percutaneous transluminal angioplasty in the treatment of infrainguinal vein bypass graft stenosis

被引:21
作者
Alexander, JQ
Katz, SG
机构
[1] Huntington Mem Hosp, Dept Surg, Div Vasc Surg, Pasadena, CA 91105 USA
[2] Univ So Calif, Keck Sch Med, Dept Surg, Div Vasc Surg, Pasadena, CA USA
关键词
D O I
10.1001/archsurg.138.5.510
中图分类号
R61 [外科手术学];
学科分类号
摘要
Hypothesis: Percutaneous angioplasty would provide a durable alternative to surgical revision in the treatment of infrainguinal vein graft stenosis. Design: Outcome analysis of the results of percutaneous angioplasty of infrainguinal vein graft stenosis. Settings: Academic vascular surgical practice in a university-affiliated community hospital. Participants: All patients undergoing percutaneous intervention for infrainguinal vein graft stenosis from January 1, 1995, to May 31, 2002, were enrolled in the study. Interventions: Lower extremity arterial reconstruction was performed by one of us. Proximal and distal sites of graft placement were identified, as well as the conduit used. Percutaneous angioplasty was performed on grafts by 1 of 4 interventional radiologists. Criteria for intervention and the anatomic location of intervention were noted. Morbidity from percutaneous intervention was also determined. Main Outcome Measures: Success and durability of percutaneous angioplasty were determined by clinical follow-up, duplex surveillance, and arteriography. Failure was defined as duplex ultrasonographic or arteriographic documentation of stenosis of 75% or greater. Kaplan-Meier life table analysis was applied to all grafts in the study. Results: Ninety-four patients with 101 grafts were included in the study. Nearly 35% of angioplasties had failed at 6 months, 53.6% had failed at 12 months, 60.6% had failed at 24 months, and 75.1% had failed at 36 months. Comorbid disease, use of anticoagulant medications, criteria for intervention, or anatomic location of percutaneous intervention did not affect patency. tight angioplasties (7.9%) were associated with significant complications. Conclusions: Percutaneous angioplasty does not provide a durable solution to the problem of infrainguinal vein graft stenosis. Because of the high rate of complications, its routine use cannot be advocated.
引用
收藏
页码:510 / 513
页数:4
相关论文
共 19 条
[1]   Surgical and endovascular intervention for infrainguinal vein graft stenosis [J].
Avino, AJ ;
Bandyk, DF ;
Gonsalves, AJ ;
Johnson, BL ;
Black, TJ ;
Zwiebel, BR ;
Rahaim, MJ ;
Cantor, A .
JOURNAL OF VASCULAR SURGERY, 1999, 29 (01) :60-70
[2]   DURABILITY OF VEIN GRAFT REVISION - THE OUTCOME OF SECONDARY PROCEDURES [J].
BANDYK, DF ;
BERGAMINI, TM ;
TOWNE, JB ;
SCHMITT, DD ;
SEABROOK, GR .
JOURNAL OF VASCULAR SURGERY, 1991, 13 (02) :200-210
[3]   MONITORING FUNCTIONAL PATENCY OF INSITU SAPHENOUS-VEIN BYPASSES - THE IMPACT OF A SURVEILLANCE PROTOCOL AND ELECTIVE REVISION [J].
BANDYK, DF ;
SCHMITT, DD ;
SEABROOK, GR ;
ADAMS, MB ;
TOWNE, JB .
JOURNAL OF VASCULAR SURGERY, 1989, 9 (02) :286-296
[4]   Infrainguinal arterial reconstruction with nonreversed greater saphenous vein [J].
Belkin, M ;
Knox, J ;
Donaldson, MC ;
Mannick, JA ;
Whittemore, AD .
JOURNAL OF VASCULAR SURGERY, 1996, 24 (06) :957-962
[5]  
BERKOWITZ HD, 1981, SURGERY, V90, P971
[6]   REVERSED VEIN GRAFT STENOSIS - EARLY DIAGNOSIS AND MANAGEMENT [J].
BERKOWITZ, HD ;
FOX, AD ;
DEATON, DH .
JOURNAL OF VASCULAR SURGERY, 1992, 15 (01) :130-142
[7]  
COHEN JR, 1986, ARCH SURG-CHICAGO, V121, P758
[8]   SURGICAL-TREATMENT OF THREATENED REVERSED INFRAINGUINAL VEIN GRAFTS [J].
NEHLER, MR ;
MONETA, GL ;
YEAGER, RA ;
EDWARDS, JM ;
TAYLOR, LM ;
PORTER, JM .
JOURNAL OF VASCULAR SURGERY, 1994, 20 (04) :558-565
[9]   RECOGNITION AND SURGICAL-MANAGEMENT OF PATENT BUT HEMODYNAMICALLY FAILED ARTERIAL GRAFTS [J].
OMARA, CS ;
FLINN, WR ;
JOHNSON, ND ;
BERGAN, JJ ;
YAO, JST .
ANNALS OF SURGERY, 1981, 193 (04) :467-476
[10]  
PERLER BA, 1990, J CARDIOVASC SURG, V31, P656