Characterization of biliary strictures using intraductal ultrasonography: comparison with percutaneous cholangioscopic biopsy

被引:126
作者
Tamada, K [1 ]
Ueno, N [1 ]
Tomiyama, T [1 ]
Oohashi, A [1 ]
Wada, S [1 ]
Nishizono, T [1 ]
Tano, S [1 ]
Aizawa, T [1 ]
Ido, K [1 ]
Kimura, K [1 ]
机构
[1] Jichi Med Sch, Dept Gastroenterol, Minami Kawachi, Tochigi 32904, Japan
关键词
D O I
10.1016/S0016-5107(98)70216-0
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: We determined the accuracy of intraductal ultrasonography (IDUS) in distinguishing between bite duct cancer and benign bile duct disease. Methods: Patients (n = 42) who required bile duct biopsy using percutaneous transhepatic cholangioscopy (PTCS) to evaluate bile duct strictures or filling defects were studied. A thin-caliber ultrasonic probe (2.0 mm diameter and 20 MHz frequency) was inserted into the bile duct, and its images were prospectively reviewed before PTCS. Results: Disruption of the bile duct wall structure, seen on IDUS, was associated with malignancy in 25 of 26 patients. When IDUS demonstrated a lesion with normal bile duct structure, six of nine patients were found to have no malignancy. IDUS demonstrated no intraductal lesion in seven patients, and bile duct biopsy also did not indicate cancer in any of these patients. The accuracy, sensitivity, and specificity of IDUS for diagnosing bile duct cancer were 76%, 89%, and 50%, respectively. When used in tandem with IDUS, the sensitivity of bile cytology (64%) and PTCS (93%) improved to 96% and 100%, respectively Conclusions: The accuracy of IDUS for diagnosing bile duct cancer was less than that of PTCS (95%). However, the sensitivity for bile cytology, or bile duct biopsy improved when performed in combination with IDUS.
引用
收藏
页码:341 / 349
页数:9
相关论文
共 39 条
[1]  
COBB CJ, 1985, ACTA CYTOL, V29, P93
[2]   BILIARY CYTODIAGNOSIS - BILE SAMPLING FOR CYTOLOGY [J].
COHAN, RH ;
ILLESCAS, FF ;
NEWMAN, GE ;
BRAUN, SD ;
DUNNICK, NR .
INVESTIGATIVE RADIOLOGY, 1985, 20 (02) :177-179
[3]   INTRALUMINAL ULTRASONOGRAPHY DURING ERCP WITH HIGH-FREQUENCY ULTRASOUND CATHETERS [J].
CUSHING, GL ;
FITZGERALD, PJ ;
BOMMER, WJ ;
ANDREWS, MW ;
CRONAN, MS ;
MARTINEZTORRES, GG ;
JANG, YT ;
BELEF, WM ;
PRINDIVILLE, TP .
GASTROINTESTINAL ENDOSCOPY, 1993, 39 (03) :432-435
[4]   VALUE OF EXFOLIATIVE CYTOLOGY FOR INVESTIGATING BILE-DUCT STRICTURES [J].
DAVIDSON, B ;
VARSAMIDAKIS, N ;
DOOLEY, J ;
DEERY, A ;
DICK, R ;
KURZAWINSKI, T ;
HOBBS, K .
GUT, 1992, 33 (10) :1408-1411
[5]  
DESSA LA, 1991, GUT, V32, P1188
[6]   ENDOLUMINAL ULTRASOUND OF THE BILE-DUCTS [J].
ENGSTROM, CF ;
WIECHEL, KL .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1990, 4 (04) :187-190
[7]   BRUSH CYTOLOGY DURING ERCP FOR THE DIAGNOSIS OF BILIARY AND PANCREATIC MALIGNANCIES [J].
FERRARI, AP ;
LICHTENSTEIN, DR ;
SLIVKA, A ;
CHANG, C ;
CARRLOCKE, DL .
GASTROINTESTINAL ENDOSCOPY, 1994, 40 (02) :140-145
[8]  
FOUTCH PG, 1990, AM J GASTROENTEROL, V85, P791
[9]  
FURUKAWA T, 1992, J ULTRAS MED, V11, P607
[10]   EXPERIENCE WITH A CATHETER-BASED ULTRASOUND PROBE IN THE BILE-DUCT AND PANCREAS [J].
GRESS, F ;
CHEN, YK ;
SHERMAN, S ;
SAVIDES, T ;
ZAIDI, S ;
JAFFE, P ;
LEHMAN, G ;
WONN, MJ ;
HAWES, R .
ENDOSCOPY, 1995, 27 (02) :178-184