Controlled breathing protocols probe human autonomic cardiovascular rhythms

被引:128
作者
Cooke, WH
Cox, JF
Diedrich, AM
Taylor, JA
Beightol, LA
Ames, JE
Hoag, JB
Seidel, H
Eckberg, DL
机构
[1] Hunter Holmes McGuire Dept Vet Affairs Med Ctr, Richmond, VA 23249 USA
[2] Virginia Commonwealth Univ, Med Coll Virginia, Dept Med, Richmond, VA 23249 USA
[3] Virginia Commonwealth Univ, Med Coll Virginia, Dept Physiol, Richmond, VA 23249 USA
[4] Virginia Commonwealth Univ, Med Coll Virginia, Dept Math Sci, Richmond, VA 23249 USA
[5] Hebrew Rehabil Ctr Aged, Brookline, MA 02167 USA
[6] Deutsch Forsch Anstalt Luft & Raumfahrt, Inst Aerosp Med, D-51147 Cologne, Germany
[7] Univ Berlin, Inst Theoret Phys, D-10623 Berlin, Germany
来源
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY | 1998年 / 274卷 / 02期
关键词
respiratory sinus arrhythmia; power spectra; R-R interval;
D O I
10.1152/ajpheart.1998.274.2.H709
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to determine how breathing protocols requiring varying degrees of control affect cardiovascular dynamics. We measured inspiratory volume, end-tidal CO2, R-R interval, and arterial pressure spectral power in 10 volunteers who followed the following 5 breathing protocols: 1) uncontrolled breathing for 5 min; 2) stepwise frequency breathing (at 0.3, 0.25, 0.2, 0.15, 0.1, and 0.05 Hz for 2 min each); 3) stepwise frequency breathing as above, but with prescribed tidal volumes; 4) random-frequency breathing (similar to 0.5-0.05 Hz) for 6 min; and 5) fixed-frequency breathing (0.25 Hz) for 5 min. During stepwise breathing, R-R interval and arterial pressure spectral power increased as breathing frequency decreased. Control of inspired volume reduced R-R interval spectral power during 0.1 Hz breathing (P < 0.05). Stepwise and random-breathing protocols yielded comparable coherence and transfer functions between respiration and R-R intervals and systolic pressure and R-R intervals. Random-and fixed-frequency breathing reduced end-tidal CO2 modestly (P < 0.05). Our data suggest that stringent tidal volume control attenuates low-frequency R-R interval oscillations and that fixed-and random-rate breathing may decrease CO2 chemoreceptor stimulation. We conclude that autonomic rhythms measured during different breathing protocols have much in common but that a stepwise protocol without stringent control of inspired volume may allow for the most efficient assessment of short-term respiratory-mediated autonomic oscillations.
引用
收藏
页码:H709 / H718
页数:10
相关论文
共 24 条
[1]  
Akselrod S., 1995, Heart Rate Variability, P147
[2]   RESPIRATORY SINUS ARRHYTHMIA - FREQUENCY DEPENDENT PHENOMENON [J].
ANGELONE, A ;
COULTER, NA .
JOURNAL OF APPLIED PHYSIOLOGY, 1964, 19 (03) :479-&
[3]   ASSESSMENT OF AUTONOMIC RESPONSE BY BROAD-BAND RESPIRATION [J].
BERGER, RD ;
SAUL, JP ;
COHEN, RJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (11) :1061-1065
[4]   IMPORTANT INFLUENCE OF RESPIRATION ON HUMAN R-R INTERVAL POWER SPECTRA IS LARGELY IGNORED [J].
BROWN, TE ;
BEIGHTOL, LA ;
KOH, J ;
ECKBERG, DL .
JOURNAL OF APPLIED PHYSIOLOGY, 1993, 75 (05) :2310-2317
[5]   RESPIRATORY SINUS ARRHYTHMIA - LAWS DERIVED FROM COMPUTER SIMULATION [J].
CLYNES, M .
JOURNAL OF APPLIED PHYSIOLOGY, 1960, 15 (05) :863-874
[6]  
COMROE JH, 1962, LUNG, P335
[7]   RELATIONSHIPS BETWEEN SHORT-TERM BLOOD-PRESSURE FLUCTUATIONS AND HEART-RATE-VARIABILITY IN RESTING SUBJECTS .1. A SPECTRAL-ANALYSIS APPROACH [J].
DEBOER, RW ;
KAREMAKER, JM ;
STRACKEE, J .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1985, 23 (04) :352-358
[8]   RESPIRATORY MODULATION OF MUSCLE SYMPATHETIC AND VAGAL CARDIAC OUTFLOW IN MAN [J].
ECKBERG, DL ;
NERHED, C ;
WALLIN, BG .
JOURNAL OF PHYSIOLOGY-LONDON, 1985, 365 (AUG) :181-196
[9]   HUMAN SINUS ARRHYTHMIA AS AN INDEX OF VAGAL CARDIAC OUTFLOW [J].
ECKBERG, DL .
JOURNAL OF APPLIED PHYSIOLOGY, 1983, 54 (04) :961-966
[10]   EFFECTS OF RESPIRATION ON BLOOD-PRESSURE AND HEART-RATE-VARIABILITY IN HUMANS [J].
ELGHOZI, JL ;
LAUDE, D ;
GIRARD, A .
CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 1991, 18 (11) :735-742