RF pulse concatenation for spatially selective inversion

被引:24
作者
Pruessmann, KP [1 ]
Golay, X
Stuber, M
Scheidegger, MB
Boesiger, P
机构
[1] Univ Zurich, Inst Biomed Engn & Med Informat, CH-8092 Zurich, Switzerland
[2] Swiss Fed Inst Technol, CH-8092 Zurich, Switzerland
[3] Johns Hopkins Univ, Kennedy Krieger Inst, Baltimore, MD 21218 USA
[4] Beth Israel Deaconess Med Ctr, Boston, MA 02215 USA
关键词
RF pulses; selective inversion; spin labeling; magnetization transfer; TILT;
D O I
10.1006/jmre.2000.2107
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
It is shown that spatially selective inversion and saturation can be achieved by concatenation of RF pulses with lower flip angles. A concatenation rule which enables global doubling of the flip angle of any given excitation pulse applied to initial z magnetization is proposed. In this fashion, the selectivity of the single pulse is preserved, making the high selectivity achievable in the low hip-angle regime available for inversion and large flip-angle saturation purposes. The profile quality achievable with exemplary concatenated pulses is investigated in comparison with adiabatic inversion. It is verified that by using concatenated inversion in the transfer insensitive labeling technique (TILT), the MT artifact is suppressed. (C) 2000 Academic Press.
引用
收藏
页码:58 / 65
页数:8
相关论文
共 18 条
[1]  
CONNOLY S, 1988, J MAGN RESON, V78, P440
[2]   PERFUSION IMAGING [J].
DETRE, JA ;
LEIGH, JS ;
WILLIAMS, DS ;
KORETSKY, AP .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) :37-45
[3]   QUALITATIVE MAPPING OF CEREBRAL BLOOD-FLOW AND FUNCTIONAL LOCALIZATION WITH ECHO-PLANAR MR-IMAGING AND SIGNAL TARGETING WITH ALTERNATING RADIO-FREQUENCY [J].
EDELMAN, RR ;
SIEWERT, B ;
DARBY, DG ;
THANGARAJ, V ;
NOBRE, AC ;
MESULAM, MM ;
WARACH, S .
RADIOLOGY, 1994, 192 (02) :513-520
[4]  
Golay X, 1999, JMRI-J MAGN RESON IM, V9, P454, DOI 10.1002/(SICI)1522-2586(199903)9:3<454::AID-JMRI14>3.3.CO
[5]  
2-2
[6]   QUANTIFICATION OF RELATIVE CEREBRAL BLOOD-FLOW CHANGE BY FLOW-SENSITIVE ALTERNATING INVERSION-RECOVERY (FAIR) TECHNIQUE - APPLICATION TO FUNCTIONAL MAPPING [J].
KIM, SG .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (03) :293-301
[7]   MR PERFUSION STUDIES WITH T-1-WEIGHTED ECHO-PLANAR IMAGING [J].
KWONG, KK ;
CHESLER, DA ;
WEISSKOFF, RM ;
DONAHUE, KM ;
DAVIS, TL ;
OSTERGAARD, L ;
CAMPBELL, TA ;
ROSEN, BR .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (06) :878-887
[8]  
LEROUX P, 1988, SOC MAGN RES MED 7 A, P1049
[9]   SIMULTANEOUS SPATIAL AND SPECTRAL SELECTIVE EXCITATION [J].
MEYER, CH ;
PAULY, JM ;
MACOVSKI, A ;
NISHIMURA, DG .
MAGNETIC RESONANCE IN MEDICINE, 1990, 15 (02) :287-304
[10]  
NORRIS DG, 1998, P ISMRM 6 ANN M SYDN, P1211