Improved mRNA quantitation in LightCycler RT-PCR

被引:21
作者
Ball, TB
Plummer, FA
HayGlass, KT
机构
[1] Univ Manitoba, Dept Immunol, Winnipeg, MB R3E 0W3, Canada
[2] Univ Manitoba, Dept Med Microbiol, Winnipeg, MB R3E 0W3, Canada
关键词
D O I
10.1159/000068372
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
Background: Real-time polymerase chain reaction (PCR) utilizing the LightCycler and similar systems is an increasingly used technique for quantitative reverse transcription (RT)-PCR of mRNA levels from genes of immunologic interest. A commonly encountered limitation with these systems is that the fluorescence induced by SYBR(R) Green (a fluorophore that binds double-stranded DNA) can result from primer dimers; (PDs) as well as the PCR product of interest, thus interfering with the ability to reproducibly quantitate mRNA levels. Methods: We use a modification of the LightCycler PCR strategy to overcome this problem by altering the PCR strategy to take advantage of the LightCycler's ability to measure fluorescence at a temperature greater than the melting point of PDs. The resulting measurements determine fluorescence of only the desired PCR product. Results: We demonstrate that by using this modified PCR strategy, one can eliminate the fluorescence induced by PDs and obtain accurate product quantitation. Conclusions: This simple modification allows more precise quantitation of sample mRNA levels by eliminating the contaminating fluorescence induced by the formation of PCR PDs. This modification obviates the need to redesign PCR primers in RT-PCR experiments where this is impractical or impossible. Copyright (C) 2003 S. Karger AG, Basel.
引用
收藏
页码:82 / 86
页数:5
相关论文
共 13 条
  • [1] The clinical usefulness of the measurement of cytokines
    Bienvenu, J
    Monneret, G
    Fabien, N
    Revillard, JP
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2000, 38 (04) : 267 - 285
  • [2] The elimination of primer-dimer accumulation in PCR
    Brownie, J
    Shawcross, S
    Theaker, J
    Whitcombe, D
    Ferrie, R
    Newton, C
    Little, S
    [J]. NUCLEIC ACIDS RESEARCH, 1997, 25 (16) : 3235 - 3241
  • [3] Absolute quantification of mRNA using real-time reverse transcription polymerase chain reaction assays
    Bustin, SA
    [J]. JOURNAL OF MOLECULAR ENDOCRINOLOGY, 2000, 25 (02) : 169 - 193
  • [4] Quantitative RT-PCR: Pitfalls and potential
    Freeman, WM
    Walker, SJ
    Vrana, KE
    [J]. BIOTECHNIQUES, 1999, 26 (01) : 112 - +
  • [5] Harris S, 1997, BRIT J BIOMED SCI, V54, P166
  • [6] Quantitation of HCV RNA using real-time PCR and fluorimetry
    Komurian-Pradel, F
    Paranhos-Baccalà, G
    Sodoyer, M
    Chevallier, P
    Mandrand, B
    Lotteau, V
    André, P
    [J]. JOURNAL OF VIROLOGICAL METHODS, 2001, 95 (1-2) : 111 - 119
  • [7] Morrison TB, 1998, BIOTECHNIQUES, V24, P954
  • [8] Rapid and sensitive quantification of Borrelia burgdorferi-infected mouse tissues by continuous fluorescent monitoring of PCR
    Morrison, TB
    Ma, Y
    Weis, JH
    Weis, JJ
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1999, 37 (04) : 987 - 992
  • [9] Relative expression software tool (REST©) for group-wise comparison and statistical analysis of relative expression results in real-time PCR -: art. no. e36
    Pfaffl, MW
    Horgan, GW
    Dempfle, L
    [J]. NUCLEIC ACIDS RESEARCH, 2002, 30 (09)
  • [10] Cytokine mRNA expression in patients with mild allergic asthma following low dose or cumulative dose allergen provocation
    Prieto, J
    Van Der Ploeg, I
    Roquet, A
    Gigliotti, D
    Dahlén, B
    Eklund, A
    Grunewald, J
    [J]. CLINICAL AND EXPERIMENTAL ALLERGY, 2001, 31 (05) : 791 - 800