Improved rotor current control of wind turbine driven doubly-fed induction generators during network voltage unbalance

被引:28
作者
Hu, Jiabing [1 ]
He, Yikang [1 ]
Xu, Lie [2 ]
机构
[1] Zhejiang Univ, Coll Elect Engn, Hangzhou 310027, Zhejiang, Peoples R China
[2] Queens Univ Belfast, Sch Elect Elect Engn & Comp Sci, Belfast BT9 5AH, Antrim, North Ireland
基金
中国国家自然科学基金;
关键词
Wind power; DFIG; Converter; Unbalance; Control design; DFIG;
D O I
10.1016/j.epsr.2009.12.010
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper investigates an improved control and operation of a doubly-fed induction generator (DFIG) system under unbalanced network conditions. A new rotor current control scheme is presented, which consists of a main controller and an auxiliary compensator. The main controller is constructed in the same way as the conventional vector control design without involving sequential-component decomposition in order to guarantee system stability and high transient response. While the auxiliary controller is specially designed to control the negative sequence current taking into account the impact of the main controller on negative sequence components. Simulated results on a commercial 1.5-MW DFIG system and experimental tests on a 1.5-kW DFIG prototype are provided and compared with those of conventional vector control and dual PI current control schemes to demonstrate the effectiveness of the proposed control strategy during steady-state and transient conditions when the network voltage is unbalanced. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:847 / 856
页数:10
相关论文
共 13 条
[1]   Control of back-to-back PWM converters for DFIG wind turbine systems under unbalanced grid voltage [J].
Abo-Khalil, Ahmed G. ;
Lee, Dong-Choon ;
Jang, Jeong-Ik .
2007 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, PROCEEDINGS, VOLS 1-8, 2007, :2637-+
[2]   Control of a doubly fed induction wind generator under unbalanced grid voltage conditions [J].
Brekken, Ted K. A. ;
Mohan, Ned .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (01) :129-135
[3]  
Chomát M, 2002, IEE CONF PUBL, P329, DOI 10.1049/cp:20020138
[4]  
CODD I, 2003, P 4 INT WORKSH LARG
[5]  
Hu J.B., 2006, Journal of Zhejiang University Science A, V7, P1757, DOI DOI 10.1631/JZUS.2006.A1757
[6]   Enhanced control of DFIG-used back-to-back PWM VSC under unbalanced grid voltage conditions [J].
Hu, Jia-Bing ;
He, Yi-Kang ;
Nian, Heng .
JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2007, 8 (08) :1330-1339
[7]   Modeling and enhanced control of DFIG under unbalanced grid voltage conditions [J].
Hu, Jiabing ;
He, Yikang .
ELECTRIC POWER SYSTEMS RESEARCH, 2009, 79 (02) :273-281
[8]  
*NAT GRID TRANSC, 2004, EXTR GRID COD CONN C
[9]  
PARK HG, 2007, 7 INT C POW EL DRIV, P1301
[10]   A NEW APPROACH TO HARMONIC COMPENSATION IN POWER-SYSTEMS - A COMBINED SYSTEM OF SHUNT PASSIVE AND SERIES ACTIVE-FILTERS [J].
PENG, FZ ;
AKAGI, H ;
NABAE, A .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1990, 26 (06) :983-990