Assay of Colistin and Colistin Methanesulfonate in Plasma and Urine by Liquid Chromatography-Tandem Mass Spectrometry

被引:125
作者
Gobin, Patrice [1 ,3 ]
Lemaitre, Florian [1 ,3 ]
Marchand, Sandrine [1 ,2 ,3 ]
Couet, William [1 ,2 ,3 ]
Olivier, Jean-Christophe [1 ,2 ]
机构
[1] INSERM, ERI 23, F-86000 Poitiers, France
[2] Univ Poitiers, Fac Med & Pharm, F-86000 Poitiers, France
[3] CHU Poitiers, F-86000 Poitiers, France
关键词
INTRAVENOUS COLISTIN; INFECTIONS; THERAPY; SAMPLES;
D O I
10.1128/AAC.01367-09
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
A rapid high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay was developed for the routine quantification of colistins A and B and their prodrugs, colistin methanesulfonate (CMS) A and CMS B, respectively, in human plasma and urine by using polymyxin B1 as the internal standard (IS). CMS concentrations were determined indirectly by subtracting the colistin concentrations determined in biological samples from the whole colistin concentrations determined after sample treatment with sulfuric acid in order to hydrolyze CMS into colistin. After extraction on a solid-phase extraction column, the colistins were separated on an XBrigde C-18 column with isocratic elution (run time, 3.8 min). The mobile phase was 0.1% (vol/vol) formic acid in acetonitrile -0.1% (vol/vol) formic acid in water (20: 80, vol/vol), run at a 0.2-ml/min flow rate. Ions were detected in the turbo-ion-spray-positive and multiple-reaction-monitoring modes. The ions monitored (precursor [M + 2H](2+) to product ions) were m/z 585.5/101.2 for colistin A, m/z 578.5/101.2 for colistin B, and m/z 602.5/241.2 for IS. Prevalidation studies demonstrated the stability of CMS in biological samples and extracts, a key point for the reliable quantification of colistin and CMS. The assay was accurate and reproducible for the quantification of colistins A and B and CMSs A and B in plasma samples over concentration ranges appropriate for pharmacokinetic studies: 0.024 to 6.144, 0.015 to 3.856, 0.029 to 7.492, and 0.010 to 2.508 mu g/ml, respectively. In urine samples, the assay was validated over the same concentration ranges for colistins and over concentration ranges of 0.058 to 7.492 mu g/ml and 0.020 to 2.508 mu g/ml for CMSs A and B, respectively.
引用
收藏
页码:1941 / 1948
页数:8
相关论文
共 18 条
[1]   Colistin methanesulfonate is an inactive prodrug of colistin against Pseudomonas aeruginosa [J].
Bergen, Phillip J. ;
Li, Jian ;
Rayner, Craig R. ;
Nation, Roger L. .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2006, 50 (06) :1953-1958
[2]   Hyphenated liquid chromatographic method for the determination of colistin residues in bovine tissues [J].
Decolin, D ;
Leroy, P ;
Nicolas, A ;
Archimbault, P .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1997, 35 (12) :557-564
[3]   Toxicity of polymyxins: a systematic review of the evidence from old and recent studies [J].
Falagas, Matthew E. ;
Kasiakou, Sofia K. .
CRITICAL CARE, 2006, 10 (01)
[4]  
GREGOIRE N, 2008, 48 INT C ANT AG CHEM
[5]   Quantitative analysis of colistin A and colistin B in plasma and culture medium using a simple precipitation step followed by LC/MS/MS [J].
Jansson, Britt ;
Karvanen, Matti ;
Cars, Otto ;
Plachouras, Diamantis ;
Friberg, Lena E. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2009, 49 (03) :760-767
[6]   High-performance liquid chromatographic method for the determination of colistin in serum [J].
Le Brun, PPH ;
de Graaf, AI ;
Vinks, AATMM .
THERAPEUTIC DRUG MONITORING, 2000, 22 (05) :589-593
[7]   Intravenous colistin as therapy for nosocomial infections caused by multidrug-resistant Pseudomonas aeruginosa and Acinetobacter baumannii [J].
Levin, AS ;
Barone, AA ;
Penço, J ;
Santos, MV ;
Marinho, IS ;
Arruda, EAG ;
Manrique, EI ;
Costa, SF .
CLINICAL INFECTIOUS DISEASES, 1999, 28 (05) :1008-1011
[8]   Pharmacokinetics of colistin methanesulphonate and colistin in rats following an intravenous dose of colistin methanesulphonate [J].
Li, J ;
Milne, RW ;
Nation, RL ;
Turnidge, JD ;
Smeaton, TC ;
Coulthard, K .
JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2004, 53 (05) :837-840
[9]   Stability of colistin and colistin methanesulfonate in aqueous media and plasma as determined by high-performance liquid chromatography [J].
Li, J ;
Milne, RW ;
Nation, RL ;
Turnidge, JD ;
Coulthard, K .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2003, 47 (04) :1364-1370
[10]   Simple method for assaying colistin methanesulfonate in plasma and urine using high-performance liquid chromatography [J].
Li, J ;
Milne, RW ;
Nation, RL ;
Turnidge, JD ;
Coulthard, K ;
Valentine, J .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2002, 46 (10) :3304-3307