Polymeric cation-exchange monolithic columns containing phosphoric acid functional groups for capillary liquid chromatography of peptides and proteins

被引:42
作者
Chen, Xin [1 ]
Tolley, H. Dennis [2 ]
Lee, Milton L. [1 ]
机构
[1] Brigham Young Univ, Dept Chem & Biochem, Provo, UT 84602 USA
[2] Brigham Young Univ, Dept Stat, Provo, UT 84602 USA
关键词
Capillary liquid chromatography; Monolith; Ion exchange; Peptides; Proteins; VARIANT SEPARATIONS; ADSORPTION; PURIFICATION; CHEMISTRY; DEVICES;
D O I
10.1016/j.chroma.2010.04.032
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Two different monoliths, both containing phosphoric acid functional groups and polyethylene glycol (PEG) functionalities were synthesized for cation-exchange chromatography of peptides and proteins. Phosphoric acid 2-hydroxyethyl methacrylate (PAHEMA) and bis[2-(methacryloyloxy)ethyl] phosphate (BMEP) were reacted with polyethylene glycol diacrylate (PEGDA) and polyethylene glycol acrylate (PEGA), respectively, in 75-mu m id. UV-transparent fused-silica capillaries by photo-initiated polymerization. The hydrophobicities of the monoliths were evaluated using propyl paraben under reversed-phase conditions and synthetic peptides under ion-exchange conditions. The resulting monoliths exhibited lower hydrophobicities than strong cation-exchange monoliths previously reported using PEGDA as cross-linker. Dynamic binding capacities of 31.2 and 269 mg/mL were measured for the PAHEMA-PEGDA and BMEP-PEGA monoliths, respectively. Synthetic peptides were eluted from both monoliths in 15 min without addition of acetonitrile to the mobile phase. Peak capacities of 50 and 31 were measured for peptides and proteins, respectively, using a PAHEMA-PEGDA monolith. The BMEP-PEGA monolith showed negligible hydrophobicity. A peak capacity of 31 was measured for the BMEP-PEGA monolith when a 20-min salt gradient rate was used to separate proteins. The effects of functional group concentration, mobile phase pH, salt gradient rate, and hydrophobicity on the retention of analytes were investigated. Good run-to-run [relative standard deviation (RSD) < 1.99%] and column-to-column (RSD < 5.64) reproducibilities were achieved. The performance of the monoliths in ion-exchange separation of peptides and proteins was superior to other polymeric monolithic columns reported previously when organic solvents were not added to the mobile phase. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:3844 / 3854
页数:11
相关论文
共 42 条
[1]   PROTEIN-PURIFICATION - THE RIGHT STEP AT THE RIGHT TIME [J].
BONNERJEA, J ;
OH, S ;
HOARE, M .
BIO-TECHNOLOGY, 1986, 4 (11) :954-&
[2]  
BURKE TWL, 1989, J CHROMATOGR, V476, P377
[3]   Polymeric strong cation-exchange monolithic column for capillary liquid chromatography of peptides and proteins [J].
Chen, Xin ;
Tolley, H. Dennis ;
Lee, Milton L. .
JOURNAL OF SEPARATION SCIENCE, 2009, 32 (15-16) :2565-2573
[4]   STRONG-CATION-EXCHANGE SULFOETHYL ASPARTAMIDE CHROMATOGRAPHY FOR PEPTIDE-MAPPING OF STAPHYLOCOCCUS-AUREUS V8-PROTEIN DIGESTS [J].
CRIMMINS, DL ;
THOMA, RS ;
MCCOURT, DW ;
SCHWARTZ, BD .
ANALYTICAL BIOCHEMISTRY, 1989, 176 (02) :255-260
[5]   Controlling the surface chemistry and chromatography properties of methyacrylate-ester-based monolithic capillary colums via photografting [J].
Eeltink, Sebastiaan ;
Hilder, Emily F. ;
Geiser, Laurent ;
Svec, Frantisek ;
Frechet, Jean M. J. ;
Rozing, Gerard P. ;
Schoenmakers, Peter J. ;
Kok, Wim Th. .
JOURNAL OF SEPARATION SCIENCE, 2007, 30 (03) :407-413
[6]   Characterisation of grafted weak anion-exchange methacrylate monoliths [J].
Frankovic, Vida ;
Podgornik, Ales ;
Krajnc, Nika Lendero ;
Smrekar, Franc ;
Krajnc, Peter ;
Strancar, Ales .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1207 (1-2) :84-93
[7]   Ring-opening metathesis polymerization for the preparation of norbornene-based weak cation-exchange monolithic capillary columns [J].
Gatschelhofer, Christina ;
Mautner, Agnes ;
Reiter, Franz ;
Pieber, Thomas R. ;
Buchmeiser, Michael R. ;
Sinner, Frank M. .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (13) :2651-2657
[8]   Preparation of weak cation exchange packings based on monodisperse poly(glycidyl methacrylate-co-ethylene dimethacrylate) beads and their chromatographic properties [J].
Gong, BL ;
Ke, CY ;
Geng, XD .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 375 (06) :769-774
[9]  
GU B, 2006, ANAL CHEM, V78, P3579
[10]   Preparation and evaluation of poly (polyethylene glycol methyl ether acrylate-co-polyethylene glycol diacrylate) monolith for protein analysis [J].
Gu, BH ;
Armenta, JM ;
Lee, ML .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1079 (1-2) :382-391