Cardiac output measured by lithium dilution, thermodilution, and transesophageal Doppler echocardiography in anesthetized horses

被引:85
作者
Linton, RA [1 ]
Young, LE
Marlin, DJ
Blissitt, KJ
Brearley, JC
Jonas, MM
O'Brien, TK
Linton, NW
Band, DM
Hollingworth, C
Jones, RS
机构
[1] St Thomas Hosp, Rayne Inst, London SE1 7EH, England
[2] Ctr Equine Studies, Anim Hlth Trust, Newmarket CB8 7UU, Suffolk, England
[3] Univ Edinburgh, Royal Sch Vet Studies, Dept Vet Clin Studies, Roslin EH25 9RG, Midlothian, Scotland
[4] Southampton Gen Hosp, Dept Anaesthet, Southampton SO16 6YD, Hants, England
[5] Univ Liverpool, Royal Liverpool Hosp, Dept Anaesthesia, Liverpool L69 3BX, Merseyside, England
关键词
D O I
10.2460/ajvr.2000.61.731
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective-To assess the suitability of lithium dilution as a method for measuring cardiac output in anesthetized horses, compared with thermodilution and transesophageal Doppler echocardiography. Animals-6 horses (3 Thoroughbreds, 3 crossbreeds). Procedure-Cardiac output was measured in 6 anesthetized horses as lithium dilution cardiac output (LiDCO), thermodilution cardiac output (TDCO), and transesophageal Doppler echocardiographic cardiac output (DopplerCO). For the LiDCO measurements, lithium chloride was administered IV, and cardiac output was derived from the arterial lithium dilution curve. Sodium nitroprusside, phenylephrine hydrochloride, and dobutamine hydrochloride were used to alter cardiac output. Experiments were divided into 4 periods. During each period, 3 LiDCO measurements, 3 DopplerCO measurements, and 3 sets of 3 TDCO measurements were obtained. Results-70 comparisons were made between LiDCO, DopplerCO, and triplicate TDCO measurements over a range of 10 to 43 L/min. The mean (+/- SD) of the differences of LiDCO - TDCO was -0.86 +/- 2.80 L/min; UDCO = -1.90 + 1.05 TDCO (r = 0.94). The mean of the differences of DopplerCO - TDCO was 1.82 +/- 2.67 L/min; DopplerCO = 2.36 +/- 0.98 TDCO (r = 0.94). The mean of the differences of LiDCO - DopplerCO was -2.68 +/- 3.01 Vmin; LiDCO = -2.53 + 0.99 DopplerCO (r = 0.93). Conclusions and Clinical Relevance- These results indicate that lithium dilution is a suitable method for measuring cardiac output in horses. As well as being accurate, it avoids the need for pulmonary artery catheterization and is quick and safe to use. Monitoring cardiac output during anesthesia in horses may help reduce the high anesthetic mortality in this species.
引用
收藏
页码:731 / 737
页数:7
相关论文
共 37 条
[1]   The shape of indicator dilution curves used for cardiac output measurement in man [J].
Band, DM ;
Linton, RAF ;
OBrien, TK ;
Jonas, MM ;
Linton, NWF .
JOURNAL OF PHYSIOLOGY-LONDON, 1997, 498 (01) :225-229
[2]  
Blissitt K J, 1995, Equine Vet J Suppl, P38
[3]   Measurement of cardiac output in standing horses by Doppler echocardiography and thermodilution [J].
Blissitt, KJ ;
Young, LE ;
Jones, RS ;
Darke, PGG ;
Utting, J .
EQUINE VETERINARY JOURNAL, 1997, 29 (01) :18-25
[4]   The effectiveness of right heart catheterization in the initial care of critically ill patients [J].
Connors, AF ;
Speroff, T ;
Dawson, NV ;
Thomas, C ;
Harrell, FE ;
Wagner, D ;
Desbiens, N ;
Goldman, L ;
Wu, AW ;
Califf, RM ;
Fulkerson, WJ ;
Vidaillet, H ;
Broste, S ;
Bellamy, P ;
Lynn, J ;
Knaus, WA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (11) :889-897
[5]  
DUNLOP CI, 1991, AM J VET RES, V52, P1893
[6]  
EBERLY VE, 1968, AM J VET RES, V29, P305
[7]   CARDIAC OUTPUT IN HORSES [J].
FISHER, EW ;
DALTON, RG .
NATURE, 1959, 184 (4704) :2020-2021
[8]  
GILLESPIE JR, 1969, AM J VET RES, V30, P61
[9]  
GRANDY JL, 1987, AM J VET RES, V48, P192
[10]  
Grosenbaugh DA, 1998, AM J VET RES, V59, P101