Spike detection .1. Correlation and reliability of human experts

被引:65
作者
Wilson, SB
Harner, RN
Duffy, FH
Tharp, BR
Nuwer, MR
Sperling, MR
机构
[1] Persyst Consulting Services, Inc., Belmar, NJ 07719
来源
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY | 1996年 / 98卷 / 03期
关键词
EEG; epilepsy; spike detection; human expert; correlation; sensitivity; psychometric theory;
D O I
10.1016/0013-4694(95)00221-9
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A panel of 5 experienced electroencephalographers detected spikes in EEG trials from 40 epilepsy patients and 10 control subjects. 1952 spikes were detected, and detailed attribute scores were recorded. Statistics from the theory of measurement error are utilized to quantify the reliability and difficulty of the study. An extension of the Pearson correlation coefficient, called the detection correlation coefficient, is derived and used in recognition of the fact that the readers agree on numerous non-spike regions. Spike perception is modeled with both dichotomous and continuous values. As expected, the study reliability is higher when using the continuous values. Standard sensitivity and specificity definitions are extended and applied to continuous-valued spike perception. A database of ''panel scores'' was created from the 5 reader scorings by merging spikes within 75 msec on each side. The average inter-reader correlation is 0.79 with a corresponding reliability of 0.95. Average spike attributes are calculated, and the resulting database can serve as a ''gold standard'' for testing computer algorithms or other readers.
引用
收藏
页码:186 / 198
页数:13
相关论文
共 17 条
[1]   FEATURE-BASED DETECTION OF THE K-COMPLEX WAVE IN THE HUMAN ELECTROENCEPHALOGRAM USING NEURAL NETWORKS [J].
BANKMAN, IN ;
SIGILLITO, VG ;
WISE, RA ;
SMITH, PL .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (12) :1305-1310
[2]   THE VALIDATION OF A NEW AMBULATORY SPIKE AND WAVE MONITOR [J].
BESAG, FMC ;
MILLS, M ;
WARDALE, F ;
ANDREW, CM ;
CRAGGS, MD .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1989, 73 (02) :157-161
[3]   SPIKE DETECTION BASED ON A PATTERN-RECOGNITION APPROACH USING A MICROCOMPUTER [J].
DEOLIVEIRA, PG ;
QUEIROZ, C ;
DASILVA, FL .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1983, 56 (01) :97-103
[4]   AUTOMATED INTERICTAL EEG SPIKE DETECTION USING ARTIFICIAL NEURAL NETWORKS [J].
GABOR, AJ ;
SEYAL, M .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1992, 83 (05) :271-280
[5]  
GOSE EE, 1974, P SAN DIEGO BIOMED S, V13, P193
[6]   STATE DEPENDENT SPIKE DETECTION - VALIDATION [J].
GOTMAN, J ;
WANG, LY .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1992, 83 (01) :12-18
[7]   COMPARISON OF TRADITIONAL READING OF EEG AND AUTOMATIC RECOGNITION OF INTERICTAL EPILEPTIC ACTIVITY [J].
GOTMAN, J ;
GLOOR, P ;
SCHAUL, N .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1978, 44 (01) :48-60
[8]  
HARNER RN, 1976, QUANTITATIVE ANAL ST
[9]  
HART JCD, 1994, INT J PSYCHOPHYSIOL, V16, P121
[10]   ASSESSMENT OF A COMPUTER-PROGRAM TO DETECT EPILEPTIFORM SPIKES [J].
HOSTETLER, WE ;
DOLLER, HJ ;
HOMAN, RW .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1992, 83 (01) :1-11