Diagnosis of patent foramen ovale using contrast-enhanced dynamic MRI:: A pilot study

被引:43
作者
Mohrs, OK
Petersen, SE
Erkapic, D
Rubel, C
Schräder, R
Nowak, B
Fach, WA
Kauczor, HU
Voigtlaender, T
机构
[1] Cardiovasc Ctr Bethanien, Dept Cardiovasc MRI, D-60389 Frankfurt, Germany
[2] German Canc Res Ctr, D-6900 Heidelberg, Germany
[3] Univ Oxford, John Radcliffe Hosp, Ctr Cardiovasc Magnet Resonance, Oxford OX3 9DU, England
关键词
D O I
10.2214/ajr.184.1.01840234
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The aim of this study was to evaluate the feasibility of dynamic contrast-enhanced MRI for detection of patent foramen ovale. SUBJECTS AND METHODS. Fifteen patients with and five patients without patent foramen ovale underwent transesophageal echocardiography and MRI, which were performed during the Valsalva maneuver. Grading results (grade 0, no patent foramen ovale and grades 1-3, minor to major enhancement due to intracardiac shunt) were assessed visually. Signal-intensity curves in the left atrium and in a pulmonary vein served to underline the diagnosis. RESULTS. The diagnoses of all patients with (15/15) and without patent foramen ovale (5/5) were correct compared with the findings of the reference transesophageal echocardiography. In 12 (60%) of 20 patients, the grading scores were identical, and in four (20%) of 20 patients, the scores differed by more than one grade. Overall, there was a good correlation of grading scores (r = 0.7, p < 0.05). Using signal-intensity curves, we found that the patients with patent foramen ovale showed an additional signal peak in the left atrium before the enhancement of the pulmonary vein because of an intracardiac shunt. In three of 15 patients with patent foramen ovale, an atrial septal aneurysm was correctly diagnosed. CONCLUSION. This pilot study shows that MRI is a new noninvasive method to detect patent foramen ovate and atrial septal aneurysm. A grading is possible but warrants further investigation regarding its predictive value and impact on treatment strategies.
引用
收藏
页码:234 / 240
页数:7
相关论文
共 24 条
[1]   Frequency of atrial septal aneurysms in patients with cerebral ischemic events [J].
Agmon, Y ;
Khandheria, BK ;
Meissner, I ;
Gentile, F ;
Whisnant, JP ;
Sicks, JD ;
O'Fallon, WM ;
Covalt, JL ;
Wiebers, DO ;
Seward, JB .
CIRCULATION, 1999, 99 (15) :1942-1944
[2]   Transcranial Doppler and risk of recurrence in patients with stroke and patent foramen ovale [J].
Anzola, GP ;
Zavarize, P ;
Morandi, E ;
Rozzini, L ;
Parrinello, G .
EUROPEAN JOURNAL OF NEUROLOGY, 2003, 10 (02) :129-135
[3]  
Beerbaum P, 2001, CIRCULATION, V103, P2476
[4]   COMPARISON OF TRANSESOPHAGEAL AND TRANSTHORACIC ECHOCARDIOGRAPHY WITH CONTRAST AND COLOR-FLOW DOPPLER IN THE DETECTION OF PATENT FORAMEN OVALE [J].
BELKIN, RN ;
POLLACK, BD ;
RUGGIERO, ML ;
ALAS, LL ;
TATINI, U .
AMERICAN HEART JOURNAL, 1994, 128 (03) :520-525
[5]   Stroke recurrence in patients with patent foramen ovale: The Lausanne Study [J].
Bogousslavsky, J ;
Garazi, S ;
Jeanrenaud, X ;
Aebischer, N ;
VanMelle, G .
NEUROLOGY, 1996, 46 (05) :1301-1305
[6]   Transcatheter closure of interatrial communications for secondary prevention of paradoxical embolism - Single-center experience [J].
Bruch, L ;
Parsi, A ;
Grad, MO ;
Rux, S ;
Burmeister, T ;
Krebs, H ;
Kleber, FX .
CIRCULATION, 2002, 105 (24) :2845-2848
[7]   DETECTION OF PATENT FORAMEN OVALE BY CONTRAST TRANSESOPHAGEAL ECHOCARDIOGRAPHY [J].
CHEN, WJ ;
KUAN, PL ;
LIEN, WP ;
LIN, FY .
CHEST, 1992, 101 (06) :1515-1520
[8]  
De Castro S, 2000, AM J CARDIOL, V86, p51G
[9]   Optimizing the technique of contrast transcranial Doppler ultrasound in the detection of right-to-left shunts [J].
Droste, DW ;
Lakemeier, S ;
Wichter, T ;
Stypmann, J ;
Dittrich, R ;
Ritter, M ;
Moeller, M ;
Freund, M ;
Ringelstein, B .
STROKE, 2002, 33 (09) :2211-2216
[10]   INCIDENCE AND SIZE OF PATENT FORAMEN OVALE DURING THE 1ST 10 DECADES OF LIFE - AN AUTOPSY STUDY OF 965 NORMAL HEARTS [J].
HAGEN, PT ;
SCHOLZ, DG ;
EDWARDS, WD .
MAYO CLINIC PROCEEDINGS, 1984, 59 (01) :17-20