Cosgrove-Edwards mitral ring dynamics measured with transesophageal three-dimensional echocardiography

被引:36
作者
Dall'Agata, A
Taams, MA
Fioretti, PM
Roelandt, JRTC
Van Herwerden, LA
机构
[1] Univ Hosp Dijkzigt, Dept Cardiopulm Surg, Thoraxctr, NL-3015 GD Rotterdam, Netherlands
[2] Univ Hosp Dijkzigt, Dept Cardiol, Thoraxctr, NL-3015 GD Rotterdam, Netherlands
关键词
D O I
10.1016/S0003-4975(97)01237-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Flexible rings have been introduced for improved mitral valve annuloplasty. These rings allow systolic-diastolic variation of both the shape and the area of the valve orifice, mimicking the normal dynamics of the mitral valve ring. In humans, information on the functional behavior of the Cosgrove-Edwards ring during the cardiac cycle is limited at present. Methods. We used transesophageal three-dimensional echocardiography to analyze mitral valve rings in 19 consecutive patients who underwent annuloplasty because of severe (grade III to IV) mitral regurgitation. Fifteen patients received a Cosgrove-Edwards ring and 4 received a Carpentier ring. The acquisition for three-dimensional reconstruction was performed using the transesophageal rotational technique, immediately after operation. Horizontal cross-sections through the mitral valve ring were selected from the data sets for measurement of the dimensions and surface area of the mitral valve orifice at end-systole and end-diastole. Measurements of the flexible Cosgrove-Edwards ring and the rigid Carpentier ring were compared. Results. Adequate images-for measurements were obtained in 17 of 19 patients. The end-systolic orifice area of the Cosgrove-Edwards ring was 4.21 +/- 1.50 cm(2) (mean +/- standard deviation) and the end-diastolic area was 4.81 +/- 1.56 cm(2) (p < 0.0001). No significant change in the orifice area of the Carpentier ring was observed. Conclusions. Three-dimensional transesophageal echocardiography allows the functional assessment in vivo of mitral valve annuloplasty rings. The Cosgrove-Edwards ring maintains its flexibility early after implantation and demonstrates significant systolic-diastolic changes in the orifice area during the cardiac cycle. (C) 1998 by The Society of Thoracic Surgeons.
引用
收藏
页码:485 / 490
页数:6
相关论文
共 27 条
[1]   MULTIPLANE TRANSESOPHAGEAL ECHOCARDIOGRAPHY AND MORPHOLOGY OF REGURGITANT MITRAL-VALVES IN SURGICAL REPAIR [J].
CALDARERA, I ;
VANHERWERDEN, LA ;
TAAMS, MA ;
BOS, E ;
ROELANDT, JRTC .
EUROPEAN HEART JOURNAL, 1995, 16 (07) :999-1006
[2]  
CARPENTIER A, 1983, J THORAC CARDIOV SUR, V86, P323
[3]  
Carpentier A, 1976, MITRAL VALVE PLURIDI, P65
[4]   THE PHYSIO-RING - AN ADVANCED CONCEPT IN MITRAL-VALVE ANNULOPLASTY [J].
CARPENTIER, AF ;
LESSANA, A ;
RELLAND, JYM ;
BELLI, E ;
MIHAILEANU, S ;
BERREBI, AJ ;
PALSKY, E ;
LOULMET, DF .
ANNALS OF THORACIC SURGERY, 1995, 60 (05) :1177-1186
[5]  
CASTRO LJ, 1993, J THORAC CARDIOV SUR, V105, P643
[6]   INITIAL EXPERIENCE WITH THE COSGROVE-EDWARDS ANNULOPLASTY SYSTEM [J].
COSGROVE, DM ;
ARCIDI, JM ;
RODRIGUEZ, L ;
STEWART, WJ ;
POWELL, K ;
THOMAS, JD .
ANNALS OF THORACIC SURGERY, 1995, 60 (03) :499-504
[7]   MITRAL-VALVE ANNULOPLASTY - THE EFFECT OF THE TYPE ON LEFT-VENTRICULAR FUNCTION [J].
DAVID, TE ;
KOMEDA, M ;
POLLICK, C ;
BURNS, RJ .
ANNALS OF THORACIC SURGERY, 1989, 47 (04) :524-528
[8]  
Flachskampf F A, 1995, Am J Card Imaging, V9, P141
[9]  
FRASER AG, 1996, MITRAL VALVE DIS, P51
[10]   CURRENT CONCEPTS OF MITRAL-VALVE RECONSTRUCTION FOR MITRAL-INSUFFICIENCY [J].
GALLOWAY, AC ;
COLVIN, SB ;
BAUMANN, FG ;
HARTY, S ;
SPENCER, FC .
CIRCULATION, 1988, 78 (05) :1087-1098