Clinical evaluation of paresthesia steering with a new system for spinal cord stimulation

被引:55
作者
Holsheimer, J
Nuttin, B
King, GW
Wesselink, WA
Gybels, JM
de Sutter, P
机构
[1] Univ Twente, Dept Elect Engn, Div Biomed Engn, Inst Biomed Technol, NL-7500 AE Enschede, Netherlands
[2] Univ Hosp Gasthuisberg, Dept Neurosurg, B-3000 Louvain, Belgium
[3] Medtron Neurol Div, Minneapolis, MN USA
关键词
chronic pain; dorsal column stimulation; paresthesia steering; spinal cord stimulation; transverse tripolar electrode;
D O I
10.1097/00006123-199803000-00022
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: The goal was to evaluate, in a clinical study, the predicted performance of the transverse tripolar system for spinal cord stimulation, particularly the steering of paresthesia, paresthesia coverage, and the therapeutic range of stimulation. METHODS: Six transverse tripolar electrodes were implanted in the lower thoracic region in four patients experiencing chronic neuropathic pain. Electrode positions, relative to the spinal cord, were estimated from computed tomographic scans. A dual-channel stimulator was used for initial percutaneous tests, and an implanted single-channel stimulator was used for follow-up test sessions. Nine "balance" settings and several cathode-anode combinations were used with the dual-channel and single-channel stimulator, respectively. In each test, the increase of paresthesia coverage from the perception threshold to the discomfort threshold was registered on a body map and the corresponding; voltages were recorded. RESULTS: Paresthesia steering occurred in all but one patient. The normalized steering score, enabling quantitative comparisons of paresthesia steering among tests and patients, showed that maximum paresthesia steering occurred when the electrode was at least 3 mm dorsal to the spinal cord and centered <2 mm from its midline. Paresthesia coverage included 70 to 100% of the body up to the electrode level, unless the electrode migrated or had broken wires. The therapeutic range, defined as the discomfort/perception of paresthesia threshold ratio, varied from 1.6 to 4.0. CONCLUSION: The clinical performance of transverse tripolar stimulation is in accordance with the characteristics predicted by computer modeling. It enables finer control of paresthesia than that achieved by polarity changes in conventional spinal cord stimulation systems.
引用
收藏
页码:541 / 547
页数:7
相关论文
共 20 条
  • [1] CURRENT STATUS OF EPIDURAL SPINAL-CORD STIMULATION
    BAROLAT, G
    [J]. NEUROSURGERY QUARTERLY, 1995, 5 (02) : 98 - 124
  • [2] MAPPING OF SENSORY RESPONSES TO EPIDURAL STIMULATION OF THE INTRASPINAL NEURAL STRUCTURES IN MAN
    BAROLAT, G
    MASSARO, F
    HE, JP
    ZEME, S
    KETCIK, B
    [J]. JOURNAL OF NEUROSURGERY, 1993, 78 (02) : 233 - 239
  • [3] MULTIFACTORIAL ANALYSIS OF EPIDURAL SPINAL-CORD STIMULATION
    BAROLAT, G
    ZEME, S
    KETCIK, B
    [J]. STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 1991, 56 (02) : 77 - 103
  • [4] Dimitrijevic M R, 1980, Int Rehabil Med, V2, P76
  • [5] PERCEPTION THRESHOLD AND ELECTRODE POSITION FOR SPINAL-CORD STIMULATION
    HE, JP
    BAROLAT, G
    HOLSHEIMER, J
    STRUIJK, JJ
    [J]. PAIN, 1994, 59 (01) : 55 - 63
  • [6] Holsheimer J, 1997, NEUROSURGERY, V40, P990, DOI 10.1097/0006123-199705000-00023
  • [7] EFFECTS OF ELECTRODE GEOMETRY AND COMBINATION ON NERVE-FIBER SELECTIVITY IN SPINAL-CORD STIMULATION
    HOLSHEIMER, J
    STRUIJK, JJ
    TAS, NR
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1995, 33 (05) : 676 - 682
  • [8] Holsheimer J, 1995, ADV STER F, V11, P119
  • [9] SEGMENTAL EFFECTS OF EPIDURAL SPINAL-CORD STIMULATION IN HUMANS
    HUNTER, JP
    ASHBY, P
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 1994, 474 (03): : 407 - 419
  • [10] ELECTRONIC ASPECTS OF SPINAL-CORD STIMULATION IN MULTIPLE-SCLEROSIS
    JOBLING, DT
    TALLIS, RC
    SEDGWICK, EM
    ILLIS, LS
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1980, 18 (01) : 48 - 56