Clinical evaluation of the Shin-Nippon NVision-K 5001/Grand Seiko WR-5100K autorefractor

被引:156
作者
Davies, LN [1 ]
Mallen, EAH [1 ]
Wolffsohn, JS [1 ]
Gilmartin, B [1 ]
机构
[1] Aston Univ, Neurosci Res Inst, Sch Life & Hlth Sci, Birmingham B4 7ET, W Midlands, England
关键词
autorefraction; subjective refraction; validity; repeatability; keratometry;
D O I
10.1097/00006324-200304000-00011
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. A clinical evaluation of the Shin-Nippon NVision-K 5001 (also branded as the Grand Seiko WR-5100K) autorefractor (Japan) was performed to examine validity and repeatability compared with subjective refraction and Javal-Schiotz keratometry. Methods. Measurements of refractive error were performed on 198 eyes of 99 subjects (aged 23.2 +/- 7.4 years) subjectively (noncycloplegic) by one masked optometrist and objectively with the NVision-K autorefractor by a second optometrist. Keratometry measurements using the NVision-K were compared with the Javal-Schiotz keratometer. Intrasession repeatability of the NVision-K was also assessed on all 99 subjects together with intersession repeatability on a separate occasion separated by 7 to 14 days. Results. Refractive error as measured by the NVision-K was found to be similar (p = 0.67) to subjective refraction (difference, 0.14 +/- 0.35 D). It was both accurate and repeatable over a wide prescription range (-8.25 to +7.25 D). Keratometry as measured by the NVision-K was found to be similar (p > 0.50) to the Javal-Schiotz technique in both the horizontal and vertical meridians (horizontal: difference, 0.02 +/- 0.09 mm; vertical: difference, 0.01 +/- 0.14 mm). There was minimal bias, and the results were repeatable (horizontal: intersession difference, 0.00 +/- 0.09 mm; vertical: intersession difference, -0.01 +/- 0.12 mm). Conclusion. The open-view arrangement of the Shin-Nippon NVision-K 5001 facilitates the measurement of static refractive error and the accommodative response to real-world stimuli. Coupled with its accuracy, repeatability, and capability to measure corneal curvature, it is a valuable addition to objective instrumentation currently available to the optometrist and researcher.
引用
收藏
页码:320 / 324
页数:5
相关论文
共 20 条
[1]  
Bennett AG., 1998, CLIN VISUAL OPTICS, V3rd
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   The repeatability of automated and clinician refraction [J].
Bullimore, MA ;
Fusaro, RE ;
Adams, CW .
OPTOMETRY AND VISION SCIENCE, 1998, 75 (08) :617-622
[4]   De/colonizing the exotic: Teaching "Asian women" in a US classroom [J].
Chatterjee, P .
FRONTIERS-A JOURNAL OF WOMEN STUDIES, 2000, 21 (1-2) :87-110
[5]   Short-term keratometric variation in the human eye [J].
Cronje, S ;
Harris, WF .
OPTOMETRY AND VISION SCIENCE, 1997, 74 (06) :420-424
[6]   Repeatability and accuracy of automated refraction: A comparison of the Nikon NRK-8000, the Nidek AR-1000, and subjective refraction [J].
Elliott, M ;
Simpson, T ;
Richter, D ;
Fonn, D .
OPTOMETRY AND VISION SCIENCE, 1997, 74 (06) :434-438
[7]  
French CN., 1974, OPHTHALMIC OPTN, V14, P797
[8]   Proximal contribution to a linear static model of accommodation and vergence [J].
Hung, GK ;
Ciuffreda, KJ ;
Rosenfield, M .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1996, 16 (01) :31-41
[9]   Excess of autorefraction over subjective refraction: Dependence on age [J].
Joubert, L ;
Harris, WF .
OPTOMETRY AND VISION SCIENCE, 1997, 74 (06) :439-444
[10]  
Mallen EAH, 2001, OPHTHAL PHYSL OPT, V21, P101, DOI 10.1016/S0275-5408(00)00049-1