What will replace the mercury sphygmomanometer?

被引:61
作者
Pickering, TG [1 ]
机构
[1] Mt Sinai Med Ctr, Zena & Michael A Wiener Cardiovasc Inst, Integrat & Behav Cardiovasc Hlth Program, New York, NY 10029 USA
关键词
blood pressure measurement; oscillometric; aneroid;
D O I
10.1097/00126097-200302000-00005
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Mercury sphygmomanometers are gradually being phased out, not because of any technological advances but because of environmental concerns. While mercury is still accepted as the 'gold standard' for routine clinical measurement, it suffers from two deficiencies: poor observer technique, and problems due to poor maintenance of the devices. At the same time, there is no generally accepted alternative; the most widely advocated candidates are aneroid or oscillometric devices. Oscillometric devices have the advantages of eliminating observer error and mechanical drift, but it is suggested that the inherent limitations of the oscillometric method mean that it cannot become the gold standard for clinical measurement in individual patients. Aneroid monitors have been found in practice to be frequently deficient, and are subject to the same deficiencies in observer technique as mercury devices. Two possible but so far untested techniques are a 'hybrid' sphygmomanometer, whereby the mercury column is replaced by an electronic transducer and display, and the wideband recording technique, which has the potential of using the same basic principle as the auscultatory technique, while eliminating the human observer.
引用
收藏
页码:23 / 25
页数:3
相关论文
共 16 条
[1]   ANEROID SPHYGMOMANOMETERS - AN ASSESSMENT OF ACCURACY AT A UNIVERSITY HOSPITAL AND CLINICS [J].
BAILEY, RH ;
KNAUS, VL ;
BAUER, JH .
ARCHIVES OF INTERNAL MEDICINE, 1991, 151 (07) :1409-1412
[2]   WIDEBAND EXTERNAL PULSE RECORDING DURING CUFF DEFLATION - A NEW TECHNIQUE FOR EVALUATION OF THE ARTERIAL-PRESSURE PULSE AND MEASUREMENT OF BLOOD-PRESSURE [J].
BLANK, SG ;
WEST, JE ;
MULLER, FB ;
CODY, RJ ;
HARSHFIELD, GA ;
PECKER, MS ;
LARAGH, JH ;
PICKERING, TG .
CIRCULATION, 1988, 77 (06) :1297-1305
[3]   SPHYGMOMANOMETERS IN HOSPITAL AND FAMILY-PRACTICE - PROBLEMS AND RECOMMENDATIONS [J].
BURKE, MJ ;
TOWERS, HM ;
OMALLEY, K ;
FITZGERALD, DJ ;
OBRIEN, ET .
BRITISH MEDICAL JOURNAL, 1982, 285 (6340) :469-471
[4]   Are aneroid sphygmomanometers accurate in hospital and clinic settings? [J].
Canzanello, VJ ;
Jensen, PL ;
Schwartz, GL .
ARCHIVES OF INTERNAL MEDICINE, 2001, 161 (05) :729-731
[5]   How should we measure blood pressure in the doctor's office? [J].
Gerin, W ;
Marion, RM ;
Friedman, R ;
James, GD ;
Bovbjerg, DH ;
Pickering, TG .
BLOOD PRESSURE MONITORING, 2001, 6 (05) :257-262
[6]   Mercury sphygmomanometers should not be abandoned: An advisory statement from the council for high blood pressure research, American Heart Association [J].
Jones, DW ;
Frohlich, ED ;
Grim, CM ;
Grim, CE ;
Taubert, KA .
HYPERTENSION, 2001, 37 (02) :185-186
[7]   The mercury sphygmomanometer should be abandoned before it is proscribed [J].
Markandu, ND ;
Whitcher, F ;
Arnold, A ;
Carney, C .
JOURNAL OF HUMAN HYPERTENSION, 2000, 14 (01) :31-36
[8]   MEANING OF THE POINT OF MAXIMUM OSCILLATIONS IN CUFF PRESSURE IN THE INDIRECT MEASUREMENT OF BLOOD-PRESSURE .2. [J].
MAUCK, GW ;
SMITH, CR ;
GEDDES, LA ;
BOURLAND, JD .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1980, 102 (01) :28-33
[9]   How accurate are sphygmomanometers? [J].
Mion, D ;
Pierin, AMG .
JOURNAL OF HUMAN HYPERTENSION, 1998, 12 (04) :245-248
[10]   Ave atque vale: The centenary of clinical sphygmomanometry [J].
OBrien, E .
LANCET, 1996, 348 (9041) :1569-1570