Variability in performance of timed walk tests in pulmonary rehabilitation programs

被引:51
作者
Elpern, EH [1 ]
Stevens, D [1 ]
Kesten, S [1 ]
机构
[1] Rush Presbyterian St Lukes Med Ctr, Chicago, IL 60612 USA
关键词
exercise testing; outcome assessment; rehabilitation;
D O I
10.1378/chest.118.1.98
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objective: To describe variability in the conduct of walk tests in pulmonary rehabilitation programs. Design: Analysis of information obtained by means of a structured written questionnaire. Setting: Outpatient pulmonary rehabilitation programs in the United States and Canada. Participants: Clinical coordinators of 75 pulmonary rehabilitation programs. Interventions: None Results: Timed walk tests were obtained in 71 of 99 programs sun eyed. Considerable variability in all aspects of testing practices was evident. Fifty-seven respondents (80%) based results on a single walk. Walk tests were completed in a hallway (73%), on a walking track (9%), and on a treadmill (7%), In 29 programs (44%), a walk supervisor carried or pulled the oxygen source, while in 25 programs (38%), the oxygen was carried or pulled by the patient. Informal nonstandardized instructions were provided to patients prior to walking in 41 programs (58%), In 53 programs (76%), the walk supervisor could direct a patient to speed up, to slow down, or to rest. Evaluations of breathlessness and perceived exertion were measured during the walk by 73% and 16% of programs, respectively. Conclusions: Practices regarding performance of timed walk tests are poorly standardized among pulmonary rehabilitation programs. Further research is needed to evaluate the impact of certain variations in testing practices on test results.
引用
收藏
页码:98 / 105
页数:8
相关论文
共 18 条
[1]  
*AM ASS CARD PULM, 1998, GUID PULM REH PROGR, P55
[2]  
American Thoracic Society, 1999, AM J RESP CRIT CARE, V159, P1666
[3]  
[Anonymous], J CARDIOPULMONARY RE, DOI DOI 10.1097/00008483-199403000-00007
[4]   A SELF PACED TREADMILL WALKING TEST FOR BREATHLESS PATIENTS [J].
BEAUMONT, A ;
COCKCROFT, A ;
GUZ, A .
THORAX, 1985, 40 (06) :459-464
[5]   COMPARISON OF 6 OXYGEN DELIVERY SYSTEMS FOR COPD PATIENTS AT REST AND DURING EXERCISE [J].
BRAUN, SR ;
SPRATT, G ;
SCOTT, GC ;
ELLERSIECK, M .
CHEST, 1992, 102 (03) :694-698
[6]   2-MINUTE, 6-MINUTE, AND 12-MINUTE WALKING TESTS IN RESPIRATORY-DISEASE [J].
BUTLAND, RJA ;
PANG, J ;
GROSS, ER ;
WOODCOCK, AA ;
GEDDES, DM .
BRITISH MEDICAL JOURNAL, 1982, 284 (6329) :1607-1608
[7]   EFFECT OF ENCOURAGEMENT ON WALKING TEST-PERFORMANCE [J].
GUYATT, GH ;
PUGSLEY, SO ;
SULLIVAN, MJ ;
THOMPSON, PJ ;
BERMAN, LB ;
JONES, NL ;
FALLEN, EL ;
TAYLOR, DW .
THORAX, 1984, 39 (11) :818-822
[8]  
Honeyman P, 1996, J Cardiopulm Rehabil, V16, P63, DOI 10.1097/00008483-199601000-00008
[9]   Reliability and validity of the 12-minute distance walk in patients with chronic obstructive pulmonary disease [J].
Larson, JL ;
Covey, MK ;
Vitalo, CA ;
Alex, CG ;
Patel, M ;
Kim, MJ .
NURSING RESEARCH, 1996, 45 (04) :203-210
[10]   PORTABLE LIQUID-OXYGEN AND EXERCISE ABILITY IN SEVERE RESPIRATORY DISABILITY [J].
LEACH, RM ;
DAVIDSON, AC ;
CHINN, S ;
TWORT, CHC ;
CAMERON, IR ;
BATEMAN, NT .
THORAX, 1992, 47 (10) :781-789