Flexural properties of fiber reinforced composite using a vacuum/pressure or a manual adaptation manufacturing process

被引:81
作者
Behr, M [1 ]
Rosentritt, M [1 ]
Lang, R [1 ]
Handel, G [1 ]
机构
[1] Univ Regensburg, Dept Prosthet Dent, D-93042 Regensburg, Germany
关键词
fiber reinforced composite packing; flexure strength;
D O I
10.1016/S0300-5712(00)00031-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study investigated the influence of fiber content and water storage on the flexural strength of beams made of two fiber-reinforced composites (FRC), the Vectris and the FibreKor system. Material and methods: A manual adaptation method (FibreKor, n = 30) and a vacuum/pressure process (Vectris, n = 30) were compared using 25 x 4 x 2 mm(3) beams. One group of the Vectris (n = 10) and the FibreKor beams (n = 10) was stored in water for 24 h, a further group was thermal-cycled (TC) 6000 x 5 degrees C/55 degrees C, and a third group was stored in water for 30 days at 37 degrees C. All beams were then loaded to failure using a three-point bending test and the flexural strength was calculated. Finally, the fiber volume percent (vol%) was determined. Results: Generally, the flexural strength decreased significantly with increasing storage time independent of the investigated fiber- and/or manufacturing system. With the parameters 24 h/TC/30 days, the mean of flexural strength for the Vectris beams was 618/579/545 N/mm(2), and for FibreKor 585/534/499 N/mm(2). A fiber content of 28.1 +/- 0.4 vol% was assessed for the Vectris beams and 12.8 +/- 0.6 vol% for the FibreKor beams. After 24 h storage in water, the Vectris and the FibreKor beams demonstrated a statistically significant higher flexural strength than after 30 days storage in water. Conclusions: A vacuum/pressure manufacturing process in contrast to manual adaptation, resulted in a markedly higher fiber content, but did not necessarily lead to significantly higher flexural strength. Not only the fiber content, but also matrix composition as well as the bond between fibers and matrix determined the properties of FRC. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:509 / 514
页数:6
相关论文
共 36 条
[1]  
[Anonymous], MATERIALPRUFUNG
[2]   In-vitro study of fracture strength and marginal adaption of fibre-reinforced adhesive fixed partial inlay dentures [J].
Behr, M ;
Rosentritt, M ;
Leibrock, A ;
Schneider-Feyrer, S ;
Handel, G .
JOURNAL OF DENTISTRY, 1999, 27 (02) :163-168
[3]  
Cadiou D, 1997, PROTHESITE DENTAIRE, V124, P27
[4]  
CHOW TK, 1999, 1 INT S FIBR REINF P
[5]  
ELIAS HG, 1992, MAKROMOLEKULE TECHNO, V2, P547
[6]   Development and clinical applications of a light-polymerized fiber-reinforced composite [J].
Freilich, MA ;
Karmaker, AC ;
Burstone, CJ ;
Goldberg, AJ .
JOURNAL OF PROSTHETIC DENTISTRY, 1998, 80 (03) :311-318
[7]   THE USE OF CONTINUOUS FIBER REINFORCEMENT IN DENTISTRY [J].
GOLDBERG, AJ ;
BURSTONE, CJ .
DENTAL MATERIALS, 1992, 8 (03) :197-202
[8]  
GOLDBERG AJ, 1999, 1 INT S FIBR REINF P
[9]   REINFORCEMENT OF POLY(METHYL METHACRYLATE) WITH ULTRA-HIGH-MODULUS POLYETHYLENE FIBER [J].
GUTTERIDGE, DL .
JOURNAL OF DENTISTRY, 1992, 20 (01) :50-54
[10]  
HELLERICH W, 1992, 53479 DIN WERKST KUN, P157