摘要
In 103 patients with acute myocardial infarction, intracoronary ultrasound imaging (ICUS) was performed before and after percutaneous transluminal coronary angioplasty (PTCA) with a pre-PTCA success rate of 79 to 103 patients (76.7%), post-PTCA rate of 88 of 103 patients (85.4%), and a reversible subacute occlusion rate after initial ICUS of 3.9%. Time consumption was 7 ± 1 minute for pre-PTCA ICUS and 3 ± 1 minute for post- PTCA ICUS.
引用
收藏
页码:641 / 643
页数:3
相关论文
共 7 条
[1]   CORONARY STENTING FOR ACUTE MYOCARDIAL-INFARCTION [J].
AHMAD, T ;
WEBB, JG ;
CARERE, RR ;
DODEK, A .
AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (01) :77-80
[2]  
Batkoff BW, 1996, CATHETER CARDIO DIAG, V38, P238, DOI 10.1002/(SICI)1097-0304(199607)38:3<238::AID-CCD3>3.0.CO
[3]  
2-9
[4]  
BOCKSCH WG, 1994, CORONARY ARTERY DIS, V5, P727
[5]   IMMEDIATE ANGIOPLASTY COMPARED WITH THE ADMINISTRATION OF A THROMBOLYTIC AGENT FOLLOWED BY CONSERVATIVE TREATMENT FOR MYOCARDIAL-INFARCTION [J].
GIBBONS, RJ ;
HOLMES, DR ;
REEDER, GS ;
BAILEY, KR ;
HOPFENSPIRGER, MR ;
GERSH, BJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1993, 328 (10) :685-691
[6]   THE SAFETY OF INTRACORONARY ULTRASOUND - A MULTICENTER SURVEY OF 2207 EXAMINATIONS [J].
HAUSMANN, D ;
ERBEL, R ;
ALIBELLICHEMARIN, MJ ;
BOKSCH, W ;
CARACCIOLO, E ;
COHN, JM ;
CULP, SC ;
DANIEL, WG ;
DESCHEERDER, I ;
DIMARIO, C ;
FERGUSON, JJ ;
FITZGERALD, PJ ;
FRIEDRICH, G ;
GE, JB ;
GORGE, G ;
HANRATH, P ;
HODGSON, JM ;
ISNER, JM ;
JAIN, S ;
MAIERRUDOLPH, W ;
MOONEY, M ;
MOSES, JW ;
MUDRA, H ;
PINTO, FJ ;
SMALLING, RW ;
TALLEY, JD ;
TOBIS, JM ;
WALTER, PD ;
WEIDINGER, F ;
WERNER, GS ;
YEUNG, AC ;
YOCK, PG .
CIRCULATION, 1995, 91 (03) :623-630
[7]   INTRAVASCULAR ULTRASOUND ASSESSMENT OF LUMEN SIZE AND WALL MORPHOLOGY IN NORMAL SUBJECTS AND PATIENTS WITH CORONARY-ARTERY DISEASE [J].
NISSEN, SE ;
GURLEY, JC ;
GRINES, CL ;
BOOTH, DC ;
MCCLURE, R ;
BERK, M ;
FISCHER, C ;
DEMARIA, AN .
CIRCULATION, 1991, 84 (03) :1087-1099