A randomized trial comparing wireless capsule endoscopy with push enteroscopy for the detection of small-bowel lesions

被引:366
作者
Appleyard, M
Fireman, Z
Glukhovsky, A
Jacob, H
Shreiver, R
Kadirkamanathan, S
Lavy, A
Lewkowicz, S
Scapa, E
Shofti, R
Swain, P
Zaretsky, A
机构
[1] Royal London Hosp, Dept Gastroenterol, London E1 1BB, England
[2] Given Imaging Ltd, Yoqneam, Israel
[3] Hillel Yoffe Med Ctr, Gastroenterol Inst, Hadera, Israel
[4] Rambam Med Ctr, Dept Diagnost Radiol, Haifa, Israel
[5] Bnai Zion Med Ctr, Haifa, Israel
[6] Assaf Harofeh Med Ctr, Inst Gastroenterol Liver Dis & Nutr, Zerifin, Israel
[7] Technion Israel Inst Technol, Fac Med, Lab Anim Unit, Haifa, Israel
关键词
D O I
10.1053/gast.2000.20844
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background & Aims: Wireless capsule endoscopy is a new, painless method of imaging the entire small bowel. It has not been compared with push enteroscopy. We compared the sensitivity, specificity, and safety of capsule and push enteroscopy in detecting small-bowel lesions. Methods: Nine to 13 radiopaque, colored beads (3- 6 mm diameter) were sewn in random order inside 9 canine small bowels, half within the first meter, and confirmed on x-ray. After recovery, the number, order, and color of beads were assessed in 23 capsule enteroscopies and 9 push enteroscopies in a random order. The surgeons, push enteroscopists, capsule video interpreters, and pathologist were blinded to the others' findings. Results: The capsules identified move beads than push enteroscopy (median, 6 [range, 2-9] vs. 3 [range, 2-6 beads]; P < 0.001). The sensitivity of the capsule was 64% compared with 37% for push enteroscopy. The specificity was 92% for capsule enteroscopy and 97% for push enteroscopy. The capsules identified significantly more beads beyond the reach of the push enteroscope (median, 4 [range, 2-7] vs. 0; P < 0.0001). Hair, ingested plastic, ulceration, submucosal swelling, and worms were clearly identified by the capsule. The capsules passed safely through the animals with no significant histologic findings. Conclusions: Wireless capsule endoscopy detected move abnormalities in the small bowel than push enteroscopy.
引用
收藏
页码:1431 / 1438
页数:8
相关论文
共 19 条
[1]   Endoscopy without air insufflation. [J].
Appleyard, M ;
Gong, F ;
Mills, TN ;
Mosse, S ;
Swain, P .
GASTROINTESTINAL ENDOSCOPY, 2000, 51 (04) :AB260-AB260
[2]  
BERNER JS, 1994, AM J GASTROENTEROL, V89, P2139
[3]  
Dodda G, 1997, J Assoc Acad Minor Phys, V8, P16
[4]  
FOUTCH PG, 1993, AM J GASTROENTEROL, V88, P807
[5]  
FOUTCH PG, 1990, GASTROINTEST ENDOSC, V36, P337
[6]  
Gay G J, 1999, Gastrointest Endosc Clin N Am, V9, P115
[7]   Wireless endoscopy [J].
Gong, F ;
Swain, P ;
Mills, T .
GASTROINTESTINAL ENDOSCOPY, 2000, 51 (06) :725-729
[8]   Wireless capsule endoscopy [J].
Iddan, G ;
Meron, G ;
Glukhovsky, A ;
Swain, P .
NATURE, 2000, 405 (6785) :417-417
[9]  
Lewis B S, 1999, Gastrointest Endosc Clin N Am, V9, P1
[10]   CHRONIC GASTROINTESTINAL-BLEEDING OF OBSCURE ORIGIN - ROLE OF SMALL BOWEL ENTEROSCOPY [J].
LEWIS, BS ;
WAYE, JD .
GASTROENTEROLOGY, 1988, 94 (05) :1117-1120