Interatrial conduction measured during biventricular pacemaker implantation accurately predicts optimal paced atrioventricular intervals

被引:17
作者
Levin, Vadim
Nemeth, Margit
Colombowala, Ilyas
Massumi, Ali
Rasekh, Abdi
Cheng, He
Coles, James A., Jr.
Ujhelyi, Michael R.
Razavi, Mehdi
机构
[1] Lehigh Valley Hosp Ctr, Allentown, PA 18102 USA
[2] St Lukes Episcopal Hosp, Texas Heart Inst, Houston, TX USA
[3] Medtronic Inc, Minneapolis, MN USA
关键词
cardiac resynchronization therapy; atrioventricular optimization; interatrial conduction;
D O I
10.1111/j.1540-8167.2006.00744.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Optimizing atrioventricular (AV) delay during biventricular (BiV) pacemaker implantation can require substantial resources. Hence, a simpler method is desirable. We hypothesized that interatrial conduction time (IACT), measured at the time of BiV device implant, could be a surrogate value for the optimal AV delay. Objective: This study determined the relationship between paced IACT and the optimal paced AV delay (PAV), as determined by echocardiography. Methods: Consecutive subjects (N = 25; age = 66 +/- 10 years; M/F: 17/8) undergoing BiV pacemaker implantation and in sinus rhythm were included. Cannulation of the coronary sinus (CS) was at the operator's discretion. A quadripolar electrophysiology catheter was inserted via the guiding sheath into the inferiolateral CS to measure left atrial depolarization. The IACT was calculated as the interval between right atrial stimulation artifact and earliest deflection on the coronary sinus catheter electrogram. Subsequently, during atrial pacing the PAV was determined using transmitral pulsed wave Doppler echocardiography (iterative method). The relationship between paced IACT and PAV was then determined. Results: The mean +/- SD paced IACT and PAV were 126 +/- 25 msec and 157 +/- 23 msec, respectively. There was a strong positive correlation between the paced IACT and PAV (r = 0.73, P < 0.001). The equation describing the relationship was PAV = 0.68 * (IACT + 104) msec. Conclusions: The paced IACT has a strong correlation with the echo derived optimal PAV This method may be used to program PAV intervals without need for echocardiography in patients undergoing BiV pacemaker implantation.
引用
收藏
页码:290 / 295
页数:6
相关论文
共 22 条
[1]   Cardiac resynchronization in chronic heart failure [J].
Abraham, WT ;
Fisher, WG ;
Smith, AL ;
Delurgio, DB ;
Leon, AR ;
Loh, E ;
Kocovic, DZ ;
Packer, M ;
Clavell, AL ;
Hayes, DL ;
Ellestad, M ;
Messenger, J ;
Trupp, RJ ;
Underwood, J ;
Pickering, F ;
Truex, C ;
McAtee, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (24) :1845-1853
[3]   Effect of pacing chamber and atrioventricular delay on acute systolic function of paced patients with congestive heart failure [J].
Auricchio, A ;
Stellbrink, C ;
Block, M ;
Sack, S ;
Vogt, J ;
Bakker, P ;
Klein, H ;
Kramer, A ;
Ding, J ;
Salo, R ;
Tockman, B ;
Pochet, T ;
Spinelli, J .
CIRCULATION, 1999, 99 (23) :2993-3001
[4]   INTERATRIAL CONDUCTION DURING CARDIAC PACING [J].
AUSUBEL, K ;
KLEMENTOWICZ, P ;
FURMAN, S .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1986, 9 (06) :1026-1031
[5]   Cardiac resynchronization therapy - Part 2 - Issues during and after device [J].
Bax, JJ ;
Abraham, T ;
Barold, SS ;
Breithardt, OA ;
Fung, JWH ;
Garrigue, S ;
Gorcsan, J ;
Hayes, DL ;
Kass, DA ;
Knuuti, J ;
Leclercq, C ;
Linde, C ;
Mark, DB ;
Monaghan, MJ ;
Nihoyannopoulos, P ;
Schalij, MJ ;
Stellbrink, C ;
Yu, CM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (12) :2168-2182
[6]   Impedance cardiography as a noninvasive technique for atrioventricular interval optimization in cardiac resynchronization therapy [J].
Braun, MU ;
Schnabel, A ;
Rauwolf, T ;
Schulze, M ;
Strasser, RH .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2005, 13 (03) :223-229
[7]   Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure [J].
Bristow, MR ;
Saxon, LA ;
Boehmer, J ;
Krueger, S ;
Kass, DA ;
De Marco, T ;
Carson, P ;
DiCarlo, L ;
DeMets, D ;
White, BG ;
DeVries, DW ;
Feldman, AM .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 350 (21) :2140-2150
[8]   Automatic beat-to-beat left heart AV normalization: Is it possible? [J].
Chirife, R ;
Tentori, MC ;
Mazzetti, H ;
Dasso, D .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (11) :2103-2110
[9]   The effect of cardiac resynchronization on morbidity and mortality in heart failure [J].
Cleland, JGF ;
Daubert, J ;
Erdmann, E ;
Freemantle, N ;
Gras, D ;
Kappenberger, L ;
Tavazzi, L ;
Cleland, JGF ;
Daubert, JC ;
Erdmann, E ;
Gras, D ;
Kappenberger, L ;
Klein, W ;
Tavazzi, L ;
Poole-Wilson, PA ;
Rydén, L ;
Wedel, H ;
Wellens, HJJ ;
Uretsky, B ;
Thygesen, K ;
Böcker, D ;
Marijianowski, MMH ;
Freemantle, N ;
Calvert, MJ ;
Christ, G ;
Fruhwald, F ;
Hofmann, R ;
Krypta, A ;
Leisch, F ;
Pacher, R ;
Rauscha, F ;
Tavernier, R ;
Thomsen, PEB ;
Boesgaard, S ;
Eiskjær, H ;
Esperen, GT ;
Haarbo, J ;
Hagemann, A ;
Korup, E ;
Moller, M ;
Mortensen, P ;
Sogaard, P ;
Vesterlund, T ;
Huikuri, H ;
Niemelä, KI ;
Toivonen, L ;
Bauer, F ;
Cohen-Solal, A ;
Crocq, C ;
Djiane, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (15) :1539-1549
[10]   The CARE-HF study (CArdiac REsynchronisation in Heart Failure study): rationale, design and end-points [J].
Cleland, JGF ;
Daubert, JC ;
Erdmann, E ;
Freemantle, N ;
Gras, D ;
Kappenberger, L ;
Klein, W ;
Tavazzi, L .
EUROPEAN JOURNAL OF HEART FAILURE, 2001, 3 (04) :481-489