Validation of a new counts-based gated single photon emission computed tomography method for quantifying left ventricular systolic function: Comparison with equilibrium radionuclide angiography

被引:56
作者
Calnon, DA
Kastner, RJ
Smith, WH
Segalla, D
Beller, GA
Watson, DD
机构
[1] Univ Virginia, Hlth Sci Ctr, Dept Radiol, Charlottesville, VA 22908 USA
[2] Univ Virginia, Hlth Sci Ctr, Dept Med, Ctr Heart,Cardiovasc Div, Charlottesville, VA 22908 USA
关键词
D O I
10.1016/S1071-3581(97)90003-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Because myocardial wall thickness is smaller than the spatial resolution of single photon emission computed tomography (SPECT) imaging, changes in myocardial wall thickness are related to changes in maximum pixel counts via the partial volume effect, allowing for quantification of regional systolic wall thickening, We have dec eloped a new gated SPECT method for computing the global left ventricular ejection fraction (LVEF) based entirely on changes in maximum regional myocardial counts during systolic contraction, This new method is independent of endocardial edge detection or other geometric measurements, Methods and Results. In 23 patients the gated SPECT method was validated by comparison with radionuclide angiography, The correlation between computed LVEFs was excellent (slope = 0.97, r = 0.91), The measurement of LVEF by gated SPECT was highly reproducible, with minimal intraoperator (slope = 0.97, r = 0.97) or inter-operator (slope = 1.00, r = 0.97) variability, Measurements of regional thickening indexes were also reproducible, with a mean intraoperator correlation coefficient of 0.89 +/- 0.05 (range 0.79 to 0.95) for the 14 myocardial regions Finally, the measurement of LVEF was not significantly influenced by changes in reconstruction filter parameters over a range of cutoff frequencies from 0.16 to 0.28., Conclusions. This new counts-based gated SPECT method for measuring global left ventricular systolic function correlates well with radionuclide angiography, is highly reproducible,and has theoretic advantages over geometric methods.
引用
收藏
页码:464 / 471
页数:8
相关论文
共 15 条
  • [1] MEASUREMENT OF LEFT-VENTRICULAR EJECTION FRACTION FROM GATED TC-99M SESTAMIBI MYOCARDIAL IMAGES
    BOONYAPRAPA, S
    EKMAHACHAI, M
    THANACHAIKUN, N
    JAIPRASERT, W
    SUKTHOMYA, V
    PORAMATIKUL, N
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1995, 22 (06): : 528 - 531
  • [2] Calnon D. A., 1997, Journal of Nuclear Medicine, V38, p14P
  • [3] COOKE CD, 1994, J NUCL MED, V35, P1185
  • [4] DEPUEY EG, 1993, J NUCL MED, V34, P1871
  • [5] Left ventricular ejection fraction from gated SPET myocardial perfusion studies: A method based on the radial distribution of count rate density across the myocardial wall
    Everaert, H
    Franken, PR
    Flamen, P
    Goris, M
    Momen, A
    Bossuyt, A
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1996, 23 (12): : 1628 - 1633
  • [6] EFFECTS OF MYOCARDIAL WALL THICKNESS ON SPECT QUANTIFICATION
    GALT, JR
    GARCIA, EV
    ROBBINS, WL
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1990, 9 (02) : 144 - 150
  • [7] GERMANO G, 1995, J NUCL MED, V36, P2138
  • [8] QUANTITATION IN POSITRON EMISSION COMPUTED-TOMOGRAPHY .1. EFFECT OF OBJECT SIZE
    HOFFMAN, EJ
    HUANG, SC
    PHELPS, ME
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (03) : 299 - 308
  • [9] KUMATA S, 1994, JPN J NUCL MED, V31, P43
  • [10] MARCASSA C, 1990, J NUCL MED, V31, P173