THE LEICESTER DOPPLER PHANTOM-A DIGITAL ELECTRONIC PHANTOM FOR ULTRASOUND PULSED DOPPLER SYSTEM TESTING

被引:9
作者
Gittins, John [1 ]
Martin, Kevin [1 ]
机构
[1] Leicester Royal Infirm, Dept Med Phys, Leicester LE1 5WW, Leics, England
关键词
Ultrasound; QA; Doppler; Phantom; SIGNAL SIMULATOR; FLOW; VALIDATION; EQUIPMENT; DEVICE;
D O I
10.1016/j.ultrasmedbio.2010.01.003
中图分类号
O42 [声学];
学科分类号
070206 [声学];
摘要
Doppler flow and string phantoms have been used to assess the performance of ultrasound Doppler systems in terms of parameters such as sensitivity, velocity accuracy and sample volume registration. However, because of the nature of their construction, they cannot challenge the accuracy and repeatability of modern digital ultrasound systems or give objective measures of system performance. Electronic Doppler phantoms are able to make use of electronically generated test signals, which may be controlled precisely in terms of frequency, amplitude and timing. The Leicester Electronic Doppler Phantom uses modern digital signal processing methods and field programmable gate array technology to overcome some of the limitations of previously described electronic phantoms. In its present form, it is able to give quantitative graphical assessments of frequency response and range gate characteristics, as well as measures of dynamic range and velocity measurement accuracy. The use of direct acoustic coupling eliminates uncertainties caused by Doppler beam effects, such as intrinsic spectral broadening, but prevents their evaluation. (E-mail: john.gittins@uhl-tr.nhs.uk) (C) 2010 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:647 / 655
页数:9
相关论文
共 15 条
[1]
*AM I ULTR MED, 1993, PERF CRIT MEAS DOPPL
[2]
[Anonymous], J VASC INVEST
[3]
A DOPPLER SIGNAL SIMULATOR [J].
BASTOS, CAC ;
FISH, PJ .
CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1991, 12 (02) :177-183
[4]
A NOVEL TESTING DEVICE FOR DOPPLER ULTRASOUND EQUIPMENT [J].
EVANS, JA ;
PRICE, R ;
LUHANA, F .
PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (11) :1701-1707
[5]
Hoeks, 1997, Eur J Ultrasound, V6, P203, DOI 10.1016/S0929-8266(97)10024-6
[6]
Simulation and validation of arterial ultrasound imaging and blood flow [J].
Hoskins, Peter R. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2008, 34 (05) :693-717
[7]
VELOCITY ESTIMATION USING DUPLEX SCANNERS [J].
HOSKINS, PR ;
MCDICKEN, WN .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (02) :195-198
[8]
HOSKINS PR, 1994, TESTING DOPPLER ULTR
[9]
Validation of a new blood-mimicking fluid for use in Doppler flow test objects [J].
Ramnarine, KV ;
Nassiri, DK ;
Hoskins, PR ;
Lubbers, J .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1998, 24 (03) :451-459
[10]
THE DOPPLER SIMULATOR-DS-81, A NEW DEVICE FOR CALIBRATING DOPPLER ULTRASOUND EQUIPMENT [J].
REUTER, R ;
TRIER, HG .
ULTRASCHALL IN DER MEDIZIN, 1983, 4 (03) :188-191