A radiostereometric analysis of the Bryan® cervical disc prosthesis

被引:19
作者
Lind, Bengt [1 ]
Zoega, Bjorn
Anderson, Paul A.
机构
[1] Sahlgrens Univ Hosp, Dept Orthopaed, Gothenburg, Sweden
[2] Landspitali Univ Hosp, Reykjavik, Iceland
[3] Univ Wisconsin, Madison, WI 53706 USA
关键词
cervical disc prosthesis; anterior cervical discectomy and fusion; degenerative disc disease; radiostereometry; bone ingrowth;
D O I
10.1097/01.brs.0000259925.11230.dd
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Prospective, radiostereometric study of the Bryan (R) Cervical Disc prosthesis (Medtronic Sofamor Danek, Memphis, TN) for the treatment of a single-level disc disease of the cervical spine. Objective. To study the stability of the titanium end-plates of the disc prosthesis at the interface between the bone and prosthesis. Summary of Background Data. Cervical disc prosthesis is a motion-sparing technology in which the longevity is dependent on initial fixation as well as secondary fixation with bone ingrowth into the surface of the device. Little is known regarding the stability of this fixation with the currently studied prosthesis. Methods. Eleven patients with symptomatic cervical radiculopathy underwent implantation of a radiostereometry modified Bryan (R) prosthesis after a standard anterior cervical discectomy. The adjacent vertebrae were perioperatively marked with tantalum markers. The patients were then frequently studied with radiostereometric radiographs and evaluated for pain, and neurologic and physical function for 2 years. Results. Both titanium endplates of the device were immediately stable in 5 patients. Small but measurable changes (micromotions) were recorded in 4 patients until the 3-month examination and in 2 patients at the 3-6-month time period. All prostheses continued to be stable after 6 months until the final assessment at 2 years after surgery. The recorded micromotions did not influence the clinical results. Conclusions. The Bryan (R) prosthesis is immediately stable in many patients and is securely fixed to the bone within 3-6 months in all patients. The result of this study suggests that there is sufficient bone ingrowth on the coated surface of the Bryan (R) prosthesis endplates to stabilize securely the prosthesis.
引用
收藏
页码:885 / 890
页数:6
相关论文
共 21 条
[1]
Intervertebral disc arthroplasty [J].
Anderson, PA ;
Rouleau, JP .
SPINE, 2004, 29 (23) :2779-2786
[2]
Cervical spine outcomes questionnaire - Its development and psychometric properties [J].
BenDebba, M ;
Heller, J ;
Ducker, TB ;
Eisinger, JM .
SPINE, 2002, 27 (19) :2116-2123
[3]
COOK SD, 1988, CLIN ORTHOP RELAT R, P90
[4]
ENGH CA, 1992, CLIN ORTHOP RELAT R, P13
[5]
Intermediate follow-up after treatment of degenerative disc disease with the Bryan Cervical Disc Prosthesis: Single-level and bi-level [J].
Goffin, J ;
Van Calenbergh, F ;
van Loon, J ;
Casey, A ;
Kehr, P ;
Liebig, K ;
Lind, B ;
Logroscino, C ;
Sgrambiglia, R ;
Pointillart, V .
SPINE, 2003, 28 (24) :2673-2678
[6]
INTERMITTENT MICROMOTION AND POLYETHYLENE PARTICLES INHIBIT BONE INGROWTH INTO TITANIUM CHAMBERS IN RABBITS [J].
GOODMAN, S ;
ASPENBERG, P ;
SONG, Y ;
REGULA, D ;
LIDGREN, L .
JOURNAL OF APPLIED BIOMATERIALS, 1995, 6 (03) :161-165
[7]
EFFECT OF AMPLITUDE OF MICROMOTION ON BONE INGROWTH INTO TITANIUM CHAMBERS IMPLANTED IN THE RABBIT TIBIA [J].
GOODMAN, S ;
ASPENBERG, P .
BIOMATERIALS, 1992, 13 (13) :944-948
[8]
DIFFERENCE IN BONE INGROWTH AFTER ONE VERSUS 2 DAILY EPISODES OF MICROMOTION - EXPERIMENTS WITH TITANIUM CHAMBERS IN RABBITS [J].
GOODMAN, S ;
WANG, JS ;
DOSHI, A ;
ASPENBERG, P .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1993, 27 (11) :1419-1424
[9]
Bone ingrowth in retrieved Bryan Cervical Disc prostheses [J].
Jensen, WK ;
Anderson, PA ;
Nel, L ;
Rouleau, JP .
SPINE, 2005, 30 (22) :2497-2502
[10]
Johnson JP, 2004, NEUROSURG FOCUS, V17, P1