Cost-effectiveness of computed tomographic colonography: A prospective comparison with colonoscopy

被引:3
作者
Arnesen, R. B.
Ginnerup-Pedersen, B.
Poulsen, P. B.
Von Benzon, E.
Adamsen, S.
Laurberg, S.
Hart-Hansen, O.
机构
[1] Copenhagen Univ Hosp Hillerod, Dept Surg, Hillerod, Denmark
[2] Copenhagen Univ Hosp Hillerod, Dept Radiol, Hillerod, Denmark
[3] Aarhus Univ Hosp, Dept Radiol, DK-8000 Aarhus, Denmark
[4] Aarhus Univ Hosp, Dept Gastrointestinal Surg, DK-8000 Aarhus, Denmark
[5] MUUSMANN Res & Consulting AS, Kolding, Denmark
[6] Copenhagen Univ Hosp Herlev, Dept Gastrointestinal Surg, Herlev, Denmark
关键词
adults; colonic polyps; colonoscopy; colorectal cancer; comparative studies; computed tomographic colonography; cost-effectiveness; endoscopy; GI;
D O I
10.1080/02841850601182139
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To estimate the cost-effectiveness of detecting colorectal polyps with computed tomographic colonography (CTC) and subsequent polypectomy with primary colonoscopy (CC), using CC as the alternative strategy. Material and Methods: A marginal analysis was performed regarding 103 patients who had had CTC prior to same-day CC at two hospitals, H-I (n = 53) and H-II (n = 50). The patients were randomly chosen from surveillance and symptomatic study populations (148 at H-I and 231 at H-II). Populations, organizations, and procedures were compared. Cost data on time consumption, medication, and minor equipment were collected prospectively, while data on salaries and major equipment were collected retrospectively. The effect was the (previously published) sensitivities of CTC and CC for detection of colorectal polyps >= 6 mm (H-I, n = 148) or >= 5 mm (H-II, n = 231). Results: Thirteen patients at each center had at least one colorectal polyp >= 6 mm or >= 5 mm. CTC was the cost-effective alternative at H-I (E187 vs. E211), while CC was the cost-effective alternative at H-II (E239 vs. E192). The cost-effectiveness (costs per finding) mainly depended on the sensitivity of CTC and CC, but the depreciation of equipment and the staff's use of time were highly influential as well. Conclusion: Detection of colorectal polyps >= 6 mm or >= 5 mm with CTC, followed by polypectomy by CC, can be performed cost-effectively at some institutions with the appropriate hardware and organization.
引用
收藏
页码:259 / 266
页数:8
相关论文
共 32 条
[1]   Missed lesions and false-positive findings on computed-tomographic colonography: a controlled prospective analysis [J].
Arnesen, RB ;
Adamsen, S ;
Svendsen, LB ;
Raaschou, HO ;
von Benzon, E ;
Hansen, OH .
ENDOSCOPY, 2005, 37 (10) :937-944
[2]  
ARNESEN RB, IN PRESS ACTA RADIOL
[3]  
Bensen S, 1999, AM J GASTROENTEROL, V94, P194
[4]  
Briggs AH, 1999, Health Technol Assess, V3, P1, DOI DOI 10.3310/HTA3020
[5]   Potentially serious adverse events at CT colonography in symptomatic patients: National survey of the United Kingdom [J].
Burling, D ;
Halligan, S ;
Slater, A ;
Noakes, MJ ;
Taylor, SA .
RADIOLOGY, 2006, 239 (02) :464-471
[6]   Computed tomographic colonography (virtual colonoscopy) - A multicenter comparison with standard colonoscopy for detection of colorectal neoplasia [J].
Cotton, PB ;
Durkalski, VL ;
Benoit, PC ;
Palesch, YY ;
Mauldin, PD ;
Hoffman, B ;
Vining, DJ ;
Small, WC ;
Affronti, J ;
Rex, D ;
Kopecky, KK ;
Ackerman, S ;
Burdick, JS ;
Brewington, C ;
Turner, MA ;
Zfass, A ;
Wright, AR ;
Iyer, RB ;
Lynch, P ;
Sivak, MV ;
Butler, H .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2004, 291 (14) :1713-1719
[7]  
Drummond M., 2015, METHODS EC EVALUATIO, V4
[8]   A comparison of virtual and conventional colonoscopy for the detection of colorectal polyps [J].
Fenlon, HM ;
Nunes, DP ;
Schroy, PC ;
Barish, MA ;
Clarke, PD ;
Ferrucci, JT .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 341 (20) :1496-1503
[9]   Optimization of CT colonography technique: Prospective trial in 180 patients [J].
Fletcher, JG ;
Johnson, CD ;
Welch, TJ ;
MacCarty, RL ;
Ahlquist, DA ;
Reed, JE ;
Harmsen, WS ;
Wilson, LA .
RADIOLOGY, 2000, 216 (03) :704-711
[10]  
GINNERUP PB, 2003, GUT, V52, P1744