Effects of experimental and modeling errors on electrocardiographic inverse formulations

被引:32
作者
Cheng, LK [1 ]
Bodley, JM [1 ]
Pullan, AJ [1 ]
机构
[1] Univ Auckland, Bioengn Inst, Auckland 1, New Zealand
关键词
comparison; epicardial potential; inverse problem; modeling errors; myocardial activation time; simulation study; EPICARDIAL POTENTIALS; MYOCARDIAL ACTIVATION; HEART; GEOMETRY;
D O I
10.1109/TBME.2002.807325
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The inverse problem of electrocardiology aims to reconstruct the electrical activity occurring within the heart using information obtained noninvasively on the body surface. Potentials obtained on the torso surface can be used as input for the inverse problem and an electrical image of the heart obtained. There are a number of different inverse algorithms currently used to produce electrical images of the heart. The relative performances of these inverse algorithms at this stage is largely unknown. Although there have been many simulation studies investigating the accuracy of each of these algorithms, to date, there has been no comprehensive study which compares a wide variety of inverse methods. By performing a detailed simulation study, we compare the performances of epicardial potential [Tikhonov, Truncated singular value decomposition (TSVD), and Greensite] and myocardial activation-based (critical point) inverse simulations along with different methods of choosing, the appropriate level of regularization (optimal, L-curve, composite residual and smoothing operator, zero-crossing) to apply to each of these inverse methods. We also examine the effects of a variety of signal error, material property error, geometric error and a combination of these errors on each of the electrocardiographic inverse algorithms. Results from the simulation study show that the activation-based method is able to produce solutions which are more accurate and stable than potential-based methods especially in the presence of correlated errors such as geometric uncertainty. In general, the Greensite-Tikhonov method produced the most realistic potential-based solutions while the zero-crossing and L-curve were the preferred method for determining the regularization parameter. The presence of signal or material property error has little effect on the inverse solutions when compared with the large errors which resulted from the presence of any geometric error. In the presence of combined Gaussian and correlated errors representing conditions which may be encountered in an experimental or clinical environment, there was less variability between potential-based solutions produced by each of the inverse algorithms.
引用
收藏
页码:23 / 32
页数:10
相关论文
共 22 条
[1]   Electrical imaging of the heart [J].
Brooks, DH ;
MacLeod, RS .
IEEE SIGNAL PROCESSING MAGAZINE, 1997, 14 (01) :24-42
[2]   Comparison of potential- and activation-based formulations for the inverse problem of electrocardiology [J].
Cheng, LK ;
Bodley, JM ;
Pullan, AJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2003, 50 (01) :11-22
[3]  
COLLIFRANZONE P, 1985, CALCOLO, V22, P91
[4]   An improved method for estimating epicardial potentials from the body surface [J].
Greensite, F ;
Huiskamp, G .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1998, 45 (01) :98-104
[5]   The forward and inverse problems of electrocardiography [J].
Gulrajani, RM .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1998, 17 (05) :84-+
[6]  
Hadamard J., 1923, Lectures on Cauchy's Problem in Linear Partial Differential Equations
[7]   TRUNCATED SINGULAR VALUE DECOMPOSITION SOLUTIONS TO DISCRETE ILL-POSED PROBLEMS WITH ILL-DETERMINED NUMERICAL RANK [J].
HANSEN, PC .
SIAM JOURNAL ON SCIENTIFIC AND STATISTICAL COMPUTING, 1990, 11 (03) :503-518
[8]  
HANSEN PC, 1992, SIAM REV, V34, P560
[9]   QRS COMPLEX DURING MYOCARDIAL ISCHEMIA - EXPERIMENTAL ANALYSIS IN PORCINE HEART [J].
HOLLAND, RP ;
BROOKS, H .
JOURNAL OF CLINICAL INVESTIGATION, 1976, 57 (03) :541-550
[10]   TAILORED VERSUS REALISTIC GEOMETRY IN THE INVERSE PROBLEM OF ELECTROCARDIOGRAPHY [J].
HUISKAMP, G ;
VANOOSTEROM, A .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (08) :827-835