A compact flow injection analysis system for surface mapping of phosphate in marine waters

被引:59
作者
Lyddy-Meaney, AJ
Ellis, PS
Worsfold, PJ
Butler, ECV
McKelvie, ID
机构
[1] Monash Univ, Sch Chem, Water Studies Ctr, Clayton, Vic 3800, Australia
[2] Univ Plymouth, Plymouth Environm Res Ctr, Dept Environm Sci, Plymouth PL4 8AA, Devon, England
[3] CSIRO, Marine Res, Hobart, Tas 7001, Australia
关键词
reagent injection; reverse FIA; seawater; phosphorus; photometric detection; tangential flow filtration;
D O I
10.1016/S0039-9140(02)00428-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The design, construction and validation of a compact, portable flow injection analysis (FIA) instrument for underway analysis of phosphate in marine waters is described. This portable system employs gas pressure for reagent propulsion and computer controlled miniature solenoid valves for precise injection of multiple reagents into a flowing stream of filtered sample. A multi-reflection flow cell with a solid state LED photometer is used to detect filterable reactive phosphate (0.2 mum) as phosphomolybdenum blue. All the components are computer controlled using software developed using the LabVIEW(TM) graphical programming language. The system has the capacity for sample throughput of up to 380 phosphate analyses per hour, but in the mode described here was operated at 225 analyses per hour. Under these conditions, the system exhibited a detection limit of 0.15 muM, reproducibility of 1.95 % RSD (n = 9) and a linear response (r(2) = 0.9992) when calibrated in the field with standards in the range 0.81-3.23 muM. The system was evaluated for the mapping of phosphate concentrations in Port Phillip Bay, south eastern Australia, and during the course of a 150 km cruise, 542 analyses were performed automatically. In general, good agreement was observed between analyses obtained using the portable FIA system and those obtained from manual sampling and laboratory analysis. (C) 2002 Elsevier Science, B.V. All rights reserved.
引用
收藏
页码:1043 / 1053
页数:11
相关论文
共 30 条
[1]  
Andrew Kevin N., 1994, Analytical Chemistry, V66, p917A
[2]  
[Anonymous], STANDARD METHODS EXA
[3]   Determination of dissolved reactive phosphorus in estuarine waters using a reversed flow injection manifold [J].
Auflitsch, S ;
Peat, DMW ;
McKelvie, ID ;
Worsfold, PJ .
ANALYST, 1997, 122 (12) :1477-1480
[4]   ANALYTICAL DETERMINATION OF ORTHO-PHOSPHATE IN WATER [J].
BROBERG, O ;
PETTERSSON, K .
HYDROBIOLOGIA, 1988, 170 :45-59
[5]  
Ellis P.F.M., Unpublished Report
[6]   Separation and detection of condensed phosphates in waste waters by ion chromatography coupled with flow injection [J].
Halliwell, DJ ;
McKelvie, ID ;
Hart, BT ;
Dunhill, RH .
ANALYST, 1996, 121 (08) :1089-1093
[7]   Hydrolysis of triphosphate from detergents in a rural waste water system [J].
Halliwell, DJ ;
McKelvie, ID ;
Hart, BT ;
Dunhill, RH .
WATER RESEARCH, 2001, 35 (02) :448-454
[8]   High temporal resolution field monitoring of phosphate in the River Frome using flow injection with diode array detection [J].
Hanrahan, G ;
Gledhill, M ;
Fletcher, PJ ;
Worsfold, PJ .
ANALYTICA CHIMICA ACTA, 2001, 440 (01) :55-62
[9]  
HINDLE ME, COMMUNICATION
[10]  
Johnson K. S., 1985, MAPPING STRATEGIES C, P7