Facemasks and aerosol delivery in vivo

被引:70
作者
Erzinger, Simone
Schueepp, Karen G.
Brooks-Wildhaber, Joanne
Devadason, Sunalene G.
Wildhaber, Johannes H.
机构
[1] Univ Childrens Hosp, Head Div Resp Med, CH-8032 Zurich, Switzerland
[2] Alpine Childrens Hosp, Davos, Switzerland
[3] Univ Western Australia, Dept Paediat, Perth Med Aerosol Res Grp, Perth, WA, Australia
来源
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG | 2007年 / 20卷
关键词
aerosol delivery; face mask; inhalation therapy; lung deposition; radiolabeled aerosols; scintigraphy studies;
D O I
10.1089/jam.2007.0572
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
It has been shown in vitro that even a small air leak in the facemask can drastically reduce the efficiency of drug delivery. In addition, it has been shown that drug deposition on the face does significantly add to overall drug loss and has the potential of local side effects. The aim of this study is therefore to verify these findings in vivo. Eight asymptomatic recurrently wheezy children, aged 18-36 months, inhaled a radiolabeled salbutamol formulation either from a pressurized metered-dose inhaler through a spacer with attached facemask or from a nebulizer with attached facemask. Drug deposition of radiolabeled salbutamol was assessed with a gamma camera and expressed as a percentage of the total dose. Lung deposition expressed as a percentage of the total dose (metered dose and nebulizer fill, respectively) was 0.2% and 0.3% in children who inhaled with a non-tightly fitted facemask. Lung deposition was 0.6% and 1.4% in screaming children with a tightly fitted facemask and between 4.8% and 8.2% in patients breathing normally. Overall mask deposition was between 0.8% and 5.2%. Overall face deposition was between 2.6% and 8.4%. The results from this pilot study support the results found in in vitro studies, where a facemask leak greatly reduces drug delivery to the patient.
引用
收藏
页码:S78 / S83
页数:6
相关论文
共 19 条
[1]   Aerosol therapy with valved holding chambers in young children: Importance of the facemask seal [J].
Amirav, I ;
Newhouse, MT .
PEDIATRICS, 2001, 108 (02) :389-394
[2]   Safety of budesonide inhalation suspension in infants aged six to twelve months with mild to moderate persistent asthma or recurrent wheeze [J].
Berger, WE ;
Qaqundah, PY ;
Blake, K ;
Rodriguez-Santana, J ;
Irani, AM ;
Xu, J ;
Goldman, M .
JOURNAL OF PEDIATRICS, 2005, 146 (01) :91-95
[3]  
Bisgaard H, 2004, PEDIATRICS, V113, P87
[4]   Local side-effects of inhaled corticosteroids in asthmatic children: influence of drug, dose, age, and device [J].
Dubus, JC ;
Marguet, C ;
Deschildre, A ;
Mely, L ;
Le Roux, P ;
Brouard, J ;
Huiart, L .
ALLERGY, 2001, 56 (10) :944-948
[5]   Aerosol delivery to young children by pMDI-spacer: Is facemask design important? [J].
Esposito-Festen, J ;
Ates, B ;
van Vliet, F ;
Hop, W ;
Tiddens, H .
PEDIATRIC ALLERGY AND IMMUNOLOGY, 2005, 16 (04) :348-353
[6]   Effect of a facemask leak on aerosol delivery from a pMDI-spacer system [J].
Esposito-Festen, JE ;
Ates, B ;
van Vliet, FJM ;
Verbraak, AFM ;
de Jongste, JC ;
Tiddens, HAWM .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 2004, 17 (01) :1-6
[7]   DRUG DELIVERY FROM JET NEBULIZERS [J].
EVERARD, ML ;
CLARK, AR ;
MILNER, AD .
ARCHIVES OF DISEASE IN CHILDHOOD, 1992, 67 (05) :586-591
[8]  
Hayden JT, 2004, ARCH DIS CHILD, V89, P72
[9]   Determining factors of aerosol deposition for four pMDI-spacer combinations in an infant upper airway model [J].
Janssens, HM ;
Krijgsman, A ;
Verbraak, TFM ;
Hop, WCJ ;
de Jongste, JC ;
Tiddens, HAWM .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 2004, 17 (01) :51-61
[10]   Inhalation treatment: Errors in application and difficulties in acceptance of the devices are frequent in wheezy infants and young children [J].
Marguet, C ;
Couderc, L ;
Le Roux, P ;
Jeannot, E ;
Lefay, V ;
Mallet, E .
PEDIATRIC ALLERGY AND IMMUNOLOGY, 2001, 12 (04) :224-230