A study of the feasibility of near infrared reflectance spectroscopy (NIRS) for analytical monitoring in wineries is presented, in which equations for the determination or screening of the commonest enological parameters are proposed. The training and validation sets to develop NIR general equations were built with samples (180) from different apellation d'origine, different wine types, etc. By the calibration step (partial least squares regression and cross-validation were used for multivariate calibration), major components such as ethanol, volumic mass, total acidity, pH, glycerol, colour, tonality and total polyphenol index are accurate determined by the proposed equations as compared with the reference data obtained by the official and standard emethods-determination coefficients (R 2) were higher than 0.800 (and higher than 0.900 most times) and standard error cross-validation (SECV) values were close to those of the reference methods. The proposed method also offers screening capability for components such as volatile acidity (R-2 = 0.481), organic acids (R-2 = 0.432 for malic acid, R-2 = 0.544 for tartaric acid, R-2 = 0.541 for gluconic acid)-with the exception of the accurate determination of lactic acid (0.860 and 0.35 g l(-1) for R-2 and SECV, respectively)-reducing sugars (R-2 = 0.705) and total sulphur dioxide (R-2 = 0.615). In equations validation, the correlation between the reference and NIRS methods was tested, and slope and bias values statistically not different from I and 0, respectively, were obtained for most parameters. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:81 / 88
页数:8
相关论文
共 15 条
[1]  
Albanell E, 2003, J AOAC INT, V86, P746
[2]   Analysis of fiber content in flax stems by near-infrared spectroscopy [J].
Barton, FE ;
Akin, DE ;
Morrison, WH ;
Ulrich, A ;
Archibald, DD .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2002, 50 (26) :7576-7580
[3]   Fast separation and determination of tyrosol, hydroxytyrosol and other phenolic compounds in extra-virgin olive oil by capillary zone electrophoresis with ultraviolet-diode array detection [J].
Bonoli, M ;
Montanucci, M ;
Toschi, TG ;
Lercker, G .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1011 (1-2) :163-172
[4]  
DUBERNET M, 2000, REV FRANCAISE OENOLO, V81, P10
[5]  
Eberl R., 1998, J NEAR INFRARED SPEC, V6, P133
[6]   Application of multivariate calibration to the simultaneous routine determination of ethanol, glycerol, fructose, glucose and total residual sugars in botrytized-grape sweet wines by means of near-infrared reflectance spectroscopy [J].
GarciaJares, CM ;
Medina, B .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 357 (01) :86-91
[7]  
Kupina SA, 2003, AM J ENOL VITICULT, V54, P131
[8]   Non-invasive fermentation analysis using an artificial neural network algorithm for processing near infrared spectra [J].
Li, Y ;
Brown, CW ;
Sun, FM ;
McCrady, JW ;
Traxler, RW ;
Lo, SC .
JOURNAL OF NEAR INFRARED SPECTROSCOPY, 1999, 7 (02) :101-108
[9]  
LLAMAS GA, 2003, J ANAL ATOM SPECTROM, V18, P460
[10]   High-precision, simultaneous analysis of Pt, Pd, and Rh in catalytic converter samples by carius tube dissolution and inductively coupled plasma atomic emission spectroscopy with charge-injection device detection [J].
Pennebaker, FM ;
Denton, MB .
APPLIED SPECTROSCOPY, 2001, 55 (04) :504-509